CE6855-48S6Q-HI Switch(48-Port 10G SFP+,6-Port 40GE QSFP+,Without Fan and Power Module)

Condition: NOB

RMA Warranty

support team Girl Avatar

Expert Consultant Support

Solution Support ,More Discount.
Live Chat   |   Email
7*24h Online

Description

Version Mapping

Table 2-170 lists the mappings between the CE6855-48S6Q-HI and software versions.

Table 2-170 Version mapping

Device Series Sub-series Device Model Short Name Supported Version
CE6800 CE6855 CE6855-48S6Q-HI CE6855HI V200R001C00 to V200R019C10

NOTE:

This model is not supported in V200R005C20.

Appearance and Structure

download?uuid=3c3502352fc64d7d9c9037da4975bcfe

The figures in this document are for reference only.

Figure 2-76 CE6855-48S6Q-HI
download?uuid=97677c41eb474ba7b3a28c606978fe96
1 Power supply slot 1

Applicable power modules:

  • 350 W DC power module
  • 600 W AC power module
2 Power supply slot 2

Applicable power modules:

  • 350 W DC power module
  • 600 W AC power module
3 Fan slot 1

Applicable fan modules:

  • FAN-40EA series fan modules
4 Fan slot 2

Applicable fan modules:

  • FAN-40EA series fan modules
5 Console port 6 ETH management port (RJ45)
7

Barcode label

NOTE:

This label is drawable, and you can pull it outward to view the ESN barcode and MAC address of the switch.

8 USB port
9 Forty-eight 10GE SFP+ Ethernet optical ports

Applicable modules and cables:

  • 10GE optical module (OSXD22N00, LE2MXSC80FF0 and SFP-10G-ZDWT-L not supported)
  • GE optical module
  • GE copper module (works at 10 Mbit/s, 100 Mbit/s, or 1000 Mbit/s)
  • SFP+ AOC cable
  • SFP+ high-speed cable
10 Six 40GE QSFP+ Ethernet optical ports

NOTE:

A 40GE QSFP+ port can be split into four 10GE ports.

In V200R005C00 and later versions, a QSA convertor can be installed on a 40GE interface that has been split. Installing a medium whose rate is 10 Gbit/s on the QSA convertor makes a 40GE interface function as a 10GE interface. Only the first split interface works and other three split interfaces are unavailable. If a QSA convertor is installed on an interface that is not split or a medium whose rate is not 10 Gbit/s is installed on the QSA convertor on an interface that has been split, the interface enters the Down(Transceiver type mismatch) status.

Applicable modules and cables:

  • 40GE optical module
  • QSFP+ AOC cable (QSFP+ to QSFP+)
  • QSFP+ AOC cable (QSFP+ to 4*SFP+)
  • QSFP+ high-speed cable (QSFP+ to 4*SFP+)
  • QSFP+ high-speed cable (QSFP+ to QSFP+)
11 Three port-side mounting holes for mounting brackets 12 Four power-supply-side mounting holes for mounting brackets
13 Ground screw

Slot

  • Power supply slot

    The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI) have two power supply slots, in which power modules can be installed to provide power to the chassis. A chassis can have one or two power modules. Double power modules can provide higher reliability.

    The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI) support double power modules (1+1 backup).

    • When both power modules are working properly, they equally provide power for a chassis.
    • When one power module fails, the other one provides all power required for a chassis.

    All power modules are hot swappable.

  • Fan slot

    The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI, CE6863-48S6CQ, CE6881-48S6CQ, CE6820-48S6CQ, CE6863-48S6CQ-K, CE6881-48S6CQ-K, CE6881E-48S6CQ and CE6857-48S6CQ-EI) have two fan slots, in which fan modules can be installed to cool the chassis, ensuring efficient heat dissipation and system stability. A chassis must have two working fan modules to ensure normal operating.

    All fan modules are hot swappable.

Airflow

The cooling systems of the CloudEngine 8800, 7800, 6800, and 5800 series switches have front-to-back or back-to-front airflow depending on the airflow direction of the power modules and fan modules used. The airflow direction of the power modules and fan modules required on the CloudEngine 8800, 7800, 6800, and 5800 series switches depends on how the switches are installed in cabinets. Typically, cabinets in a data center have cold air flowing in from the front and hot air exhausted from the back. If CloudEngine 8800, 7800, 6800, and 5800 series switches are installed with the power supply side facing the front, you are advised to use fan modules and power modules with front-to-back airflow in the switches.

download?uuid=3c3502352fc64d7d9c9037da4975bcfe

  • Front-to-back airflow: The power modules and fan modules using front-to-back airflow are marked download?uuid=8e3c5f3f4eb24e75bfe01e936f5de109 or download?uuid=8658d84ede1e40ee8792c4c652ba6254. Air flows into the chassis from the power supply side and flows out from the port side, as shown in Figure 2-77 (CE5800 as an example).
  • Back-to-front airflow: The power modules and fan modules using back-to-front airflow are marked download?uuid=6ec6574197184ca18310e5cd7ca0ef46 or download?uuid=a279ad38209c4849bcd709cc0b65aeb7. Air flows into the chassis from the port side and flows out from the power supply side, as shown in Figure 2-78 (CE5800 as an example).
  • When the power module and fan module use forcible heat dissipation, they must use the same airflow method. For example, if the power module with back-to-front airflow is used, the fan module with back-to-front airflow must be used.

Figure 2-77 Front-to-back airflow (air flows out from the port side)
download?uuid=d598a70a4f2142ee88f5e5b5c606cf3f
Figure 2-78 Back-to-front airflow (air flows in from the port side)
download?uuid=2cda8b4e29b34612bfc48b8b7ced03fb

Indicators

The CE6855-48S6Q-HI does not have a mode switch button and the STAT/SPEED/STACK mode indicator. The downlink service port indicators of the CE6855-48S6Q-HI are 10GE optical port indicators, and other indicators on the CE6855-48S6Q-HI are the same as those on the CE6850-48T4Q-EI. The CE6850-48T4Q-EI is used as an example here to describe the indicators.

Ports

10GE SFP+ Ethernet Optical Port

A 10GE SFP+ Ethernet optical port supports auto-sensing to 1 Gbit/s, and can receive and send services at a rate of 1000 Mbit/s or 10 Gbit/s. Table 2-171 describes the attributes of a 10GE SFP+ Ethernet optical port.

Table 2-171 Attributes of a 10GE SFP+ Ethernet optical port

Attribute

Description

Connector type

LC

Optical attributes

Depending on the module or cable in use

Standards compliance

IEEE802.3ae

Working mode

Supported rate: 1000 Mbit/s and 10 Gbit/s auto-sensing

Full-duplex

40GE QSFP+ Ethernet Optical Port

A 40GE QSFP+ Ethernet optical port receives and sends services at the rate of 40 Gbit/s. If a 40GE QSFP+ Ethernet optical port is split into four 10GE ports, it must use 1-to-4 QSFP+ optical modules and optical fibers or 1-to-4 QSFP+ cables. Table 2-172 describes the attributes of a 40GE QSFP+ Ethernet optical port.

Table 2-172 Attributes of a 40GE QSFP+ Ethernet optical port

Attribute

Description

Connector type

LC/MPO

Optical port attributes

Depending on the module or cable in use

Standards compliance

IEEE802.3ba

Working mode

Full-duplex

Console Port

The console port is connected to a console for onsite configuration. The port must use a console cable. Table 2-173 describes the attributes of the console port.

Table 2-173 Attributes of the console port

Attribute

Description

Connector type

RJ45

Standards compliance

RS232

Working mode

Duplex Universal Asynchronous Receiver/Transmitter (UART)

Baud rate

9600 bit/s to 115200 bit/s

Default value: 9600 bit/s

ETH Management Port (RJ45)

The ETH management port (RJ45) of a switch is connected to the network port of a configuration terminal or network management workstation to set up the onsite or remote configuration environment. The ETH management port (RJ45) uses a Category 5 or higher category cable. Table 2-174 describes the attributes of the ETH management port (RJ45).

Table 2-174 Attributes of the ETH management port (RJ45)

Attribute

Description

Connector type

RJ45

Standards compliance

IEEE802.3ab

Working mode

Supported rate: 10/100/1000 Mbit/s auto-sensing

Full-duplex

Maximum transmission distance

100 m

USB Port

A USB flash drive can be connected to the USB port for log backup, system software backup and uploading, or USB-based deployment.

Specifications

Table 2-175 lists technical specifications of the CE6855-48S6Q-HI switch.

Table 2-175 Technical specifications

Item Description
Physical specifications
  • Dimensions (W x D x H): 442.0 mm x 420.0 mm x 43.6 mm (17.4 in. x 16.5 in. x 1.72 in.)
  • Weight (with two power modules and two fan modules, calculated based on the heaviest model if multiple models are supported): 8.7 kg (19.18 lb)
Environment parameters Temperature
  • Operating temperature: 0°C to 40°C (32°F to 104°F) at altitude of 0-1800 m (0-5906 ft.)

    NOTE:

    When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

  • Storage temperature: -40°C to +70°C (-40°F to +158°F)
Relative humidity 5% RH to 95% RH, noncondensing
Altitude < 5000 m (16404 ft.)
Noise (sound pressure, 27°C)
  • Back-to-front airflow: < 56 dBA
  • Front-to-back airflow: < 58 dBA
Power specifications Power source type AC/DC
AC power input
  • Rated input voltage range: 100 V AC to 240 V AC, 50/60 Hz
  • Maximum input voltage range: 90 V AC to 290 V AC, 47 Hz to 63 Hz
DC power input
  • Rated voltage range: -48 V DC to -60 V DC
  • Maximum voltage range: -38.4 V DC to -72 V DC
High-voltage DC power input Not supported
Rated input current
  • 350 W DC power (PDC-350WA series): 11 A (-48 V DC to -60 V DC)
  • 600 W AC power (PAC-600WA series): 9 A (100 V AC to 240 V AC)
Chassis power consumption Maximum power consumption 216 W
Typical power consumption 116 W (100% throughput, SFP+ cables on 48 ports and QSFP+ cables on 6 ports, double power modules)
Chassis heat dissipation Maximum heat dissipation 737 BTU/hr
Typical heat dissipation 396 BTU/hr (100% throughput, SFP+ cables on 48 ports and QSFP+ cables on 6 ports, double power modules)
Surge protection

Power module:

  • AC: 6 kV in common mode and 6 kV in differential mode
  • DC: 4 kV in common mode and 2 kV in differential mode
Heat dissipation Heat dissipation mode Air cooling
Airflow Front-to-back or back-to-front, depending on the fan modules and power modules
Reliability and availability Power module backup 1+1 backup
Fan module backup 1+1 backup not supported

NOTE:

A CE6800 chassis uses two fan modules, with each fan module containing two fans. The four fans in the chassis work in 3+1 backup mode.

Hot swap Supported by all power modules and fan modules
Mean time between failures (MTBF) 48.83 years
Mean time to repair (MTTR) 1.73 hours
Availability 0.99999595166
Technical specifications Processor 1.2 GHz, quad-core
DRAM Memory 2 GB
NOR Flash 16 MB
NAND Flash 1 GB
Stack Service port supporting the stack function 10GE optical ports and 40GE optical ports
Certification
  • Safety standards compliance
  • EMC standards compliance
  • Environmental standards compliance

Ordering Information

Ordering information is subject to change without notice in the case of product upgrades. Ordering information provided in this manual is for reference only. To obtain latest ordering information, contact Huawei switch distributors or local Huawei representative office.

Table 2-176 provides the ordering information.

Table 2-176 Ordering information

Part Number Part Model Part Description
02350RTC CE6855-HI-B-B0A CE6855-48S6Q-HI Switch (48-Port 10G SFP+, 6-Port 40GE QSFP+, 2*AC Power Module, 2*FAN Box, Port-side Intake)
02350WVA CE6855-HI-B-B0B CE6855-48S6Q-HI Switch (48-Port 10G SFP+, 6-Port 40GE QSFP+, 2*AC Power Module, 2*FAN Box, Port-side Intake, 4m Ground Wire)
02350RTB CE6855-HI-F-B0A CE6855-48S6Q-HI Switch (48-Port 10G SFP+, 6-Port 40GE QSFP+, 2*AC Power Module, 2*FAN Box, Port-side Exhaust)
02350SRQ CE6855-48S6Q-HI CE6855-48S6Q-HI Switch (48-Port 10G SFP+, 6-Port 40GE QSFP+, Without Power Module and FAN Box)