E6860-48S8CQ-EI Switch(48-Port 25GE SFP28,8*100GE QSFP28,Without Fan and Power Module).

Condition: NOB

RMA Warranty

support team Girl Avatar

Expert Consultant Support

Solution Support ,More Discount.
Live Chat   |   Email
7*24h Online

Description

Version Mapping

Table 2-208 lists the mappings between the CE6860-48S8CQ-EI and software versions.

Table 2-208 Version mapping

Device Series Sub-series Device Model Short Name Supported Version
CE6800 CE6860 CE6860-48S8CQ-EI CE6860EI V200R002C50 to V200R019C10

NOTE:

This model is not supported in V200R005C20.

Appearance and Structure

download?uuid=0d6368cd488f4df7b55c040d55c631df

The figures in this document are for reference only.

Figure 2-93 CE6860-48S8CQ-EI
download?uuid=718dda70ee514f3b94d5a805f1cc4dba
1 Power supply slot 1

Applicable power modules:

  • 350 W DC power module
  • 600 W AC power module
NOTE:

At the ambient temperature of 0°C to 40°C, the 350 W DC module can be used only when all optical interfaces on the switch are equipped with the following short-distance optical modules: 25GBase-SR (power consumption ≤ 1 W) and 100GE optical modules (transmission distance ≤ 2 km; power consumption ≤ 3.5 W) such as 100GBase-SR4, 100GBase-CWDM4, 100GBase-CLR4, and 100GBase-PSM4.

2 Power supply slot 2

Applicable power modules:

  • 350 W DC power module
  • 600 W AC power module
NOTE:

At the ambient temperature of 0°C to 40°C, the 350 W DC module can be used only when all optical interfaces on the switch are equipped with the following short-distance optical modules: 25GBase-SR (power consumption ≤ 1 W) and 100GE optical modules (transmission distance ≤ 2 km; power consumption ≤ 3.5 W) such as 100GBase-SR4, 100GBase-CWDM4, 100GBase-CLR4, and 100GBase-PSM4.

3 Fan slot 1

Applicable fan modules:

  • FAN-40HA series fan modules
4 Fan slot 2

Applicable fan modules:

  • FAN-40HA series fan modules
5 Console port 6 ETH management port (RJ45)
7
Barcode label

NOTE:

This label is drawable, and you can pull it outward to view the ESN barcode and MAC address of the switch.

8 USB port
9 Forty-eight 10GE/25GE SFP28 Ethernet optical ports

Applicable modules and cables:

  • 10GE optical module (OSXD22N00, LE2MXSC80FF0 and SFP-10G-ZDWT-L not supported)
  • GE Optical Modules (supported from V200R005C00 version)
  • GE copper module (supported from V200R005C00 version and only works at 1000 Mbit/s)
  • 25GE optical module (only supports SFP-25G-SR)
  • SFP+ AOC cable
  • SFP28 AOC cable
  • SFP+ high-speed cable
  • SFP28 high-speed cable (1 m or 3 m)
NOTE:

A 25GE optical interface does not support auto-negotiation when it has a GE optical module installed. To connect the two interfaces at both ends of a link, disable auto-negotiation on the peer interface. Otherwise, one interface may go Up and the other may go Down.

10 Eight 40GE/100GE QSFP28 Ethernet optical ports

NOTE:

A QSFP28 Ethernet optical port can be split into four 10GE or 25GE ports.

Applicable modules and cables:

  • 40GE optical module
  • 100GE optical module (QSFP28-100G-4WDM-40 not supported)
  • QSFP+ to QSFP+ AOC cable
  • QSFP+ to 4*SFP+ AOC cable
  • QSFP+ to 4*SFP+ high-speed cable
  • QSFP+ to QSFP+ high-speed cable
  • QSFP28 to QSFP28 AOC cable
  • QSFP28 to QSFP28 high-speed cable
  • QSFP28 to 4*SFP28 high-speed cable (1 m or 3 m)
11 Three port-side mounting holes for mounting brackets 12 Four power-supply-side mounting holes for mounting brackets
13 Ground screw

Slot

  • Power supply slot

    The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI) have two power supply slots, in which power modules can be installed to provide power to the chassis. A chassis can have one or two power modules. Double power modules can provide higher reliability.

    The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI) support double power modules (1+1 backup).

    • When both power modules are working properly, they equally provide power for a chassis.
    • When one power module fails, the other one provides all power required for a chassis.

    All power modules are hot swappable.

  • Fan slot

    The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI, CE6863-48S6CQ, CE6881-48S6CQ, CE6820-48S6CQ, CE6863-48S6CQ-K, CE6881-48S6CQ-K, CE6881E-48S6CQ and CE6857-48S6CQ-EI) have two fan slots, in which fan modules can be installed to cool the chassis, ensuring efficient heat dissipation and system stability. A chassis must have two working fan modules to ensure normal operating.

    All fan modules are hot swappable.

Airflow

The cooling systems of the CloudEngine 8800, 7800, 6800, and 5800 series switches have front-to-back or back-to-front airflow depending on the airflow direction of the power modules and fan modules used. The airflow direction of the power modules and fan modules required on the CloudEngine 8800, 7800, 6800, and 5800 series switches depends on how the switches are installed in cabinets. Typically, cabinets in a data center have cold air flowing in from the front and hot air exhausted from the back. If CloudEngine 8800, 7800, 6800, and 5800 series switches are installed with the power supply side facing the front, you are advised to use fan modules and power modules with front-to-back airflow in the switches.

download?uuid=0d6368cd488f4df7b55c040d55c631df

  • Front-to-back airflow: The power modules and fan modules using front-to-back airflow are marked download?uuid=08a4d991512d45e99e5a6519ab183fc2 or download?uuid=882b433269ec460f9089504ec6a91f78. Air flows into the chassis from the power supply side and flows out from the port side, as shown in Figure 2-94 (CE5800 as an example).
  • Back-to-front airflow: The power modules and fan modules using back-to-front airflow are marked download?uuid=1cde3e79be6b4e2cae599e517cdd2242 or download?uuid=a919fa8f0cd94a36b8c3ce54cc66fab0. Air flows into the chassis from the port side and flows out from the power supply side, as shown in Figure 2-95 (CE5800 as an example).
  • When the power module and fan module use forcible heat dissipation, they must use the same airflow method. For example, if the power module with back-to-front airflow is used, the fan module with back-to-front airflow must be used.

Figure 2-94 Front-to-back airflow (air flows out from the port side)
download?uuid=6e3378fc2e994d71bc6dda62b12f08b4
Figure 2-95 Back-to-front airflow (air flows in from the port side)
download?uuid=8e6d6bda652544dabc99089b67a38a05

Indicators

Figure 2-96 Indicators on the CE6860-48S8CQ-EI rear panel
download?uuid=69ca1f87b1cf4f3cbf0cfa1eab4cc52d
Figure 2-97 Indicators on the CE6860-48S8CQ-EI front panel
download?uuid=2f68a62dc25f4d1ea0140be2001a48c4
Table 2-209 Indicator description

No. Indicator Name Color Status Description
1 SYS System status indicator Green Off The system is not running.
Fast blinking The system is starting.
Slow blinking The system is running normally.
Red Steady on
  • The system fails to start.
  • At least one power module does not work normally.
  • At least one fan module does not work normally.
2 MST: Stack master/slave indicator

NOTE:

In V200R003C00 and later versions, you can use the dfs-master led enable command to enable the stack master/slave indicator to display the DFS group master and backup status.

After the stack master/slave indicator is enabled to display the DFS group master and backup status, the stack master/slave indicator on the DFS master device is steady on and that on the DFS backup device is off.

Green Off The switch is not a stack master.
Steady on The switch is a stack master or standalone switch.
3 ID ID indicator Blue Off The ID indicator is not used (default state).
Steady on The indicator identifies the switch to maintain. The ID indicator can be turned on or off remotely to help field engineers find the switch to maintain.
4 Service port indicator (10GE/25GE optical port)

NOTE:

Each 10GE/25GE optical port has two single-color indicators. The one on the left is the ACT indicator (yellow), and the one on the right is the LINK indicator (green).

Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top.

Green Off No link has been established on the port or the port has been shut down.
Steady on A link is established on the port.
Yellow Off The port is not sending or receiving data.
Blinking The port is sending or receiving data.
5 Service port indicator (40GE/100GE optical port)

NOTE:

Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top.

Green Off No link has been established on the port or the port has been shut down.
Steady on A link is established on the port.
Blinking The port is sending or receiving data.
When a 40GE/100GE port is configured as four 10GE ports or four 25GE ports, this indicator shows the status of a 10GE/25GE port. The sequence number of the indicated port is identified by indicators 40G/100G Breakout 1/2/3/4 on the lower right corner of the panel.

NOTE:

Each 40GE/100GE port has a single-color indicator, which shows the status of the 40GE/100GE port by default.

6 40G/100G Breakout 1/2/3/4 (sequence number indicators of 10GE/25GE ports converted from a 40GE/100GE port)

NOTE:

Indicators 1, 2, 3, 4 turn on in cyclic order, with each indicator keeping on for 5s.

Green Off 40GE/100GE ports are working in 40GE or 100GE mode and not split into four 10GE ports or four 25GE ports.
Steady on At least one 40GE/100GE port has been split into four 10GE ports or four 25GE ports.

When one or more 40GE/100GE ports are split into four 10GE ports or four 25GE ports, these indicators identify the sequence numbers of the 10GE/25GE ports. A port indicator (6 in Figure 2-96) shows the status of a 10GE/25GE port converted from the corresponding 40GE/100GE port:

  • When indicator 1 is on, each port indicator shows the status of the first 10GE/25GE port derived from the corresponding 40GE/100GE port.
  • When indicator 2 is on, each port indicator shows the status of the second 10GE/25GE port derived from the corresponding 40GE/100GE port.
  • When indicator 3 is on, each port indicator shows the status of the third 10GE/25GE port derived from the corresponding 40GE/100GE port.
  • When indicator 4 is on, each port indicator shows the status of the fourth 10GE/25GE port derived from the corresponding 40GE/100GE port.
7 ACT USB-based deployment indicator Green Off USB-based deployment is disabled (default state).
Steady on USB-based deployment has been completed.
Blinking The system is reading data from a USB flash drive.
Red Steady on USB-based deployment has failed.
8 L/A ETH management port indicator Green Off No link is established on the port.
Steady on A link is established on the port.
Blinking The port is sending or receiving data.

Ports

10GE/25GE SFP28 Optical Port

10GE/25GE SFP28 optical ports cannot work at the rate of 100 Mbit/s. Table 2-210 shows the attributes of a 10GE/25GE SFP28 optical port.

Table 2-210 Attributes of a 10GE/25GE SFP28 optical port

Attribute

Description

Connector type

Depending on the optical module

Optical attributes

Depending on the module or cable in use

Port use constraints

The 48 10GE/25GE SFP28 optical ports of a CE6860 switch work at the rate of 25 Gbit/s by default and do not support GE/10GE auto-sensing. You can set the port rate to 10 Gbit/s or 1 Gbit/s using the port mode 10g or port mode ge command, respectively. If GE mediums are installed on the first eight 25GE interfaces, you need to run the port mode ge command to configure the interfaces to work at the rate of 1 Gbit/s; if GE mediums are installed on the later 40 25GE interfaces, the port mode 10g command needs to be run, the interfaces automatically work at the rate of 1 Gbit/s, and the port mode ge command does not need to be run.

The 48 10GE/25GE SFP28 optical ports are divided into 12 port groups, with four ports in each group (1-4, 5-8, 9-12…45-48).

  • If the rate of any port in a port group is set to 1 Gbit/s, 10 Gbit/s, or 25 Gbit/s, all the other ports in this group also work at the rate of 1 Gbit/s, 10 Gbit/s, or 25 Gbit/s.

  • When the ports in a port group work at the rate of 25 Gbit/s, they support only 25GE modules or cables and will go Down if other types of modules or cables are used. When the ports in a port group work at the rate of 10 Gbit/s, they support only 10GE or 25GE variable-rate modules or cables and will go Down if other types of modules or cables are used. When the ports in a port group work at the rate of 1 Gbit/s, they support only GE modules or cables and will go Down if other types of modules or cables are used.

  • If the switch is running a version earlier than V200R002C50, the ports in a port group must use the same type of transmission medium (copper or fiber). This constraint does not apply to V200R002C50 and later versions.

Standards compliance

IEEE802.3by

Working mode

Full-duplex

40GE/100GE QSFP28 Optical Port

Table 2-211 describes the attributes of a 40GE/100GE QSFP28 optical port.

Table 2-211 Attributes of a 40GE/100GE QSFP28 optical port

Attribute

Description

Connector type

Depending on the optical module

Optical attributes

Depending on the module or cable in use

Standards compliance

IEEE802.3ba

Working mode

Full-duplex

Console Port

The console port is connected to a console for onsite configuration. The port must use a console cable. Table 2-212 describes the attributes of the console port.

Table 2-212 Attributes of the console port

Attribute

Description

Connector type

RJ45

Standards compliance

RS232

Working mode

Duplex Universal Asynchronous Receiver/Transmitter (UART)

Baud rate

9600 bit/s to 115200 bit/s

Default value: 9600 bit/s

ETH Management Port (RJ45)

The ETH management port (RJ45) of a switch is connected to the network port of a configuration terminal or network management workstation to set up the onsite or remote configuration environment. The ETH management port (RJ45) uses a Category 5 or higher category cable. Table 2-213 describes the attributes of the ETH management port (RJ45).

Table 2-213 Attributes of the ETH management port (RJ45)

Attribute

Description

Connector type

RJ45

Standards compliance

IEEE802.3ab

Working mode

Supported rate: 10/100/1000 Mbit/s auto-sensing

Full-duplex

Maximum transmission distance

100 m

USB Port

A USB flash drive can be connected to the USB port for log backup, system software backup and uploading, or USB-based deployment.

Specifications

Table 2-214 lists technical specifications of the CE6860-48S8CQ-EI switch.

Table 2-214 Technical specifications

Item Description
Physical specifications
  • Dimensions (W x D x H): 442.0 mm x 420.0 mm x 43.6 mm (17.4 in. x 16.5 in. x 1.72 in.)
  • Weight (with two power modules and two fan modules, calculated based on the heaviest model if multiple models are supported): 8.8 kg (19.40 lb)
Environment parameters Temperature
  • Operating temperature: 0°C to 40°C (32°F to 104°F) at altitude of 0-1800 m (0-5906 ft.)
    NOTE:

    When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

  • Storage temperature: -40°C to +70°C (-40°F to +158°F)
Relative humidity 5% RH to 95% RH, noncondensing
Altitude < 5000 m (16404 ft.)
Noise (sound pressure, 27°C)
  • Back-to-front airflow: < 51 dBA
  • Front-to-back airflow: < 52 dBA
Power specifications Power source type AC/DC
AC power input
  • Rated input voltage range: 100 V AC to 240 V AC, 50/60 Hz
  • Maximum input voltage range: 90 V AC to 290 V AC, 47 Hz to 63 Hz
DC power input
  • Rated voltage range: -48 V DC to -60 V DC
  • Maximum voltage range: -38.4 V DC to -72 V DC
High-voltage DC power input Not supported
Rated input current
  • 350 W DC power (PDC-350WA series): 11 A (-48 V DC to -60 V DC)
  • 600 W AC power (PAC-600WA series): 9 A (100 V AC to 240 V AC)
Chassis power consumption Maximum power consumption 336 W
Typical power consumption 214 W (100% throughput, SFP28 cables on 48 ports and QSFP28 cables on 8 ports, double power modules)
Chassis heat dissipation Maximum heat dissipation 1146 BTU/hr
Typical heat dissipation 731 BTU/hr (100% throughput, SFP28 cables on 48 ports and QSFP28 cables on 8 ports, double power modules)
Surge protection
Power module:

  • AC: 6 kV in common mode and 6 kV in differential mode
  • DC: 2 kV in common mode and 1 kV in differential mode
Heat dissipation Heat dissipation mode Air cooling
Airflow Front-to-back or back-to-front, depending on the fan modules and power modules
Reliability and availability Power module backup 1+1 backup
Fan module backup 1+1 backup not supported

NOTE:

A CE6800 chassis uses two fan modules, with each fan module containing two fans. The four fans in the chassis work in 3+1 backup mode.

Hot swap Supported by all power modules and fan modules
Mean time between failures (MTBF) 51.50 years
Mean time to repair (MTTR) 1.67 hours
Availability 0.99999629199
Technical specifications Processor 1.5 GHz, 8-core
DRAM Memory 2 GB
NOR Flash 32 MB
NAND Flash 1 GB
Stack Service port supporting the stack function 25GE optical ports and 100GE optical ports
Certification
  • Safety standards compliance
  • EMC standards compliance
  • Environmental standards compliance

Ordering Information

Ordering information is subject to change without notice in the case of product upgrades. Ordering information provided in this manual is for reference only. To obtain latest ordering information, contact Huawei switch distributors or local Huawei representative office.

Table 2-215 provides the ordering information.

Table 2-215 Ordering information

Part Number Part Model Part Description
02350SRA CE6860-48S8CQ-EI CE6860-48S8CQ-EI Switch (48-Port 25GE SFP28, 8*100GE QSFP28, Without Fan and Power Module)
02350SBQ CE6860-EI-F-B0B CE6860-48S8CQ-EI Switch (48-Port 25GE SFP28, 8*100GE QSFP28, 2*AC Power Module, 2*FAN Box, Port-side Exhaust)
02350SBR CE6860-EI-B-B0B CE6860-48S8CQ-EI Switch (48-Port 25GE SFP28, 8*100GE QSFP28, 2*AC Power Module, 2*FAN Box, Port-side Intake)