Description
Version Mapping
Table 2-208 lists the mappings between the CE6860-48S8CQ-EI and software versions.
Appearance and Structure
The figures in this document are for reference only.
1 | Power supply slot 1
Applicable power modules:
NOTE:
At the ambient temperature of 0°C to 40°C, the 350 W DC module can be used only when all optical interfaces on the switch are equipped with the following short-distance optical modules: 25GBase-SR (power consumption ≤ 1 W) and 100GE optical modules (transmission distance ≤ 2 km; power consumption ≤ 3.5 W) such as 100GBase-SR4, 100GBase-CWDM4, 100GBase-CLR4, and 100GBase-PSM4. |
2 | Power supply slot 2
Applicable power modules:
NOTE:
At the ambient temperature of 0°C to 40°C, the 350 W DC module can be used only when all optical interfaces on the switch are equipped with the following short-distance optical modules: 25GBase-SR (power consumption ≤ 1 W) and 100GE optical modules (transmission distance ≤ 2 km; power consumption ≤ 3.5 W) such as 100GBase-SR4, 100GBase-CWDM4, 100GBase-CLR4, and 100GBase-PSM4. |
3 | Fan slot 1
Applicable fan modules:
|
4 | Fan slot 2
Applicable fan modules:
|
5 | Console port | 6 | ETH management port (RJ45) |
7 |
Barcode label
NOTE:
This label is drawable, and you can pull it outward to view the ESN barcode and MAC address of the switch. |
8 | USB port |
9 | Forty-eight 10GE/25GE SFP28 Ethernet optical ports
Applicable modules and cables:
NOTE:
A 25GE optical interface does not support auto-negotiation when it has a GE optical module installed. To connect the two interfaces at both ends of a link, disable auto-negotiation on the peer interface. Otherwise, one interface may go Up and the other may go Down. |
10 | Eight 40GE/100GE QSFP28 Ethernet optical ports
NOTE:
A QSFP28 Ethernet optical port can be split into four 10GE or 25GE ports. Applicable modules and cables:
|
11 | Three port-side mounting holes for mounting brackets | 12 | Four power-supply-side mounting holes for mounting brackets |
13 | Ground screw | – | – |
Slot
-
Power supply slot
The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI) have two power supply slots, in which power modules can be installed to provide power to the chassis. A chassis can have one or two power modules. Double power modules can provide higher reliability.
The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI) support double power modules (1+1 backup).- When both power modules are working properly, they equally provide power for a chassis.
- When one power module fails, the other one provides all power required for a chassis.
All power modules are hot swappable.
-
Fan slot
The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI, CE6863-48S6CQ, CE6881-48S6CQ, CE6820-48S6CQ, CE6863-48S6CQ-K, CE6881-48S6CQ-K, CE6881E-48S6CQ and CE6857-48S6CQ-EI) have two fan slots, in which fan modules can be installed to cool the chassis, ensuring efficient heat dissipation and system stability. A chassis must have two working fan modules to ensure normal operating.
All fan modules are hot swappable.
Airflow
- Front-to-back airflow: The power modules and fan modules using front-to-back airflow are marked
or
. Air flows into the chassis from the power supply side and flows out from the port side, as shown in Figure 2-94 (CE5800 as an example).
- Back-to-front airflow: The power modules and fan modules using back-to-front airflow are marked
or
. Air flows into the chassis from the port side and flows out from the power supply side, as shown in Figure 2-95 (CE5800 as an example).
-
When the power module and fan module use forcible heat dissipation, they must use the same airflow method. For example, if the power module with back-to-front airflow is used, the fan module with back-to-front airflow must be used.
Indicators
No. | Indicator | Name | Color | Status | Description |
---|---|---|---|---|---|
1 | SYS | System status indicator | Green | Off | The system is not running. |
Fast blinking | The system is starting. | ||||
Slow blinking | The system is running normally. | ||||
Red | Steady on |
|
|||
2 | MST: | Stack master/slave indicator
NOTE:
In V200R003C00 and later versions, you can use the dfs-master led enable command to enable the stack master/slave indicator to display the DFS group master and backup status. After the stack master/slave indicator is enabled to display the DFS group master and backup status, the stack master/slave indicator on the DFS master device is steady on and that on the DFS backup device is off. |
Green | Off | The switch is not a stack master. |
Steady on | The switch is a stack master or standalone switch. | ||||
3 | ID | ID indicator | Blue | Off | The ID indicator is not used (default state). |
Steady on | The indicator identifies the switch to maintain. The ID indicator can be turned on or off remotely to help field engineers find the switch to maintain. | ||||
4 | – | Service port indicator (10GE/25GE optical port)
NOTE:
Each 10GE/25GE optical port has two single-color indicators. The one on the left is the ACT indicator (yellow), and the one on the right is the LINK indicator (green). Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top. |
Green | Off | No link has been established on the port or the port has been shut down. |
Steady on | A link is established on the port. | ||||
Yellow | Off | The port is not sending or receiving data. | |||
Blinking | The port is sending or receiving data. | ||||
5 | – | Service port indicator (40GE/100GE optical port)
NOTE:
Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top. |
Green | Off | No link has been established on the port or the port has been shut down. |
Steady on | A link is established on the port. | ||||
Blinking | The port is sending or receiving data. | ||||
When a 40GE/100GE port is configured as four 10GE ports or four 25GE ports, this indicator shows the status of a 10GE/25GE port. The sequence number of the indicated port is identified by indicators 40G/100G Breakout 1/2/3/4 on the lower right corner of the panel.
NOTE:
Each 40GE/100GE port has a single-color indicator, which shows the status of the 40GE/100GE port by default. |
|||||
6 | – | 40G/100G Breakout 1/2/3/4 (sequence number indicators of 10GE/25GE ports converted from a 40GE/100GE port)
NOTE:
Indicators 1, 2, 3, 4 turn on in cyclic order, with each indicator keeping on for 5s. |
Green | Off | 40GE/100GE ports are working in 40GE or 100GE mode and not split into four 10GE ports or four 25GE ports. |
Steady on | At least one 40GE/100GE port has been split into four 10GE ports or four 25GE ports.
When one or more 40GE/100GE ports are split into four 10GE ports or four 25GE ports, these indicators identify the sequence numbers of the 10GE/25GE ports. A port indicator (6 in Figure 2-96) shows the status of a 10GE/25GE port converted from the corresponding 40GE/100GE port:
|
||||
7 | ACT | USB-based deployment indicator | Green | Off | USB-based deployment is disabled (default state). |
Steady on | USB-based deployment has been completed. | ||||
Blinking | The system is reading data from a USB flash drive. | ||||
Red | Steady on | USB-based deployment has failed. | |||
8 | L/A | ETH management port indicator | Green | Off | No link is established on the port. |
Steady on | A link is established on the port. | ||||
Blinking | The port is sending or receiving data. |
Ports
10GE/25GE SFP28 Optical Port
Attribute |
Description |
---|---|
Connector type |
Depending on the optical module |
Optical attributes |
Depending on the module or cable in use |
Port use constraints |
The 48 10GE/25GE SFP28 optical ports of a CE6860 switch work at the rate of 25 Gbit/s by default and do not support GE/10GE auto-sensing. You can set the port rate to 10 Gbit/s or 1 Gbit/s using the port mode 10g or port mode ge command, respectively. If GE mediums are installed on the first eight 25GE interfaces, you need to run the port mode ge command to configure the interfaces to work at the rate of 1 Gbit/s; if GE mediums are installed on the later 40 25GE interfaces, the port mode 10g command needs to be run, the interfaces automatically work at the rate of 1 Gbit/s, and the port mode ge command does not need to be run. The 48 10GE/25GE SFP28 optical ports are divided into 12 port groups, with four ports in each group (1-4, 5-8, 9-12…45-48).
|
Standards compliance |
IEEE802.3by |
Working mode |
Full-duplex |
40GE/100GE QSFP28 Optical Port
Console Port
ETH Management Port (RJ45)
USB Port
A USB flash drive can be connected to the USB port for log backup, system software backup and uploading, or USB-based deployment.
Specifications
Table 2-214 lists technical specifications of the CE6860-48S8CQ-EI switch.
Item | Description | |
---|---|---|
Physical specifications |
|
|
Environment parameters | Temperature |
|
Relative humidity | 5% RH to 95% RH, noncondensing | |
Altitude | < 5000 m (16404 ft.) | |
Noise (sound pressure, 27°C) |
|
|
Power specifications | Power source type | AC/DC |
AC power input |
|
|
DC power input |
|
|
High-voltage DC power input | Not supported | |
Rated input current |
|
|
Chassis power consumption | Maximum power consumption | 336 W |
Typical power consumption | 214 W (100% throughput, SFP28 cables on 48 ports and QSFP28 cables on 8 ports, double power modules) | |
Chassis heat dissipation | Maximum heat dissipation | 1146 BTU/hr |
Typical heat dissipation | 731 BTU/hr (100% throughput, SFP28 cables on 48 ports and QSFP28 cables on 8 ports, double power modules) | |
Surge protection |
Power module:
|
|
Heat dissipation | Heat dissipation mode | Air cooling |
Airflow | Front-to-back or back-to-front, depending on the fan modules and power modules | |
Reliability and availability | Power module backup | 1+1 backup |
Fan module backup | 1+1 backup not supported
NOTE:
A CE6800 chassis uses two fan modules, with each fan module containing two fans. The four fans in the chassis work in 3+1 backup mode. |
|
Hot swap | Supported by all power modules and fan modules | |
Mean time between failures (MTBF) | 51.50 years | |
Mean time to repair (MTTR) | 1.67 hours | |
Availability | 0.99999629199 | |
Technical specifications | Processor | 1.5 GHz, 8-core |
DRAM Memory | 2 GB | |
NOR Flash | 32 MB | |
NAND Flash | 1 GB | |
Stack | Service port supporting the stack function | 25GE optical ports and 100GE optical ports |
Certification |
|
Ordering Information
Ordering information is subject to change without notice in the case of product upgrades. Ordering information provided in this manual is for reference only. To obtain latest ordering information, contact Huawei switch distributors or local Huawei representative office.
Table 2-215 provides the ordering information.
Part Number | Part Model | Part Description |
---|---|---|
02350SRA | CE6860-48S8CQ-EI | CE6860-48S8CQ-EI Switch (48-Port 25GE SFP28, 8*100GE QSFP28, Without Fan and Power Module) |
02350SBQ | CE6860-EI-F-B0B | CE6860-48S8CQ-EI Switch (48-Port 25GE SFP28, 8*100GE QSFP28, 2*AC Power Module, 2*FAN Box, Port-side Exhaust) |
02350SBR | CE6860-EI-B-B0B | CE6860-48S8CQ-EI Switch (48-Port 25GE SFP28, 8*100GE QSFP28, 2*AC Power Module, 2*FAN Box, Port-side Intake) |