Overview
Are you looking for really simple and affordable flash storage? The HPE MSA 2062 Storage is a flash-enabled system designed to provide affordable application acceleration for small and remote office deployments. Don’t let the low cost fool you. The MSA 2062 gives you a combination of simplicity, flexibility, and advanced features you might not expect in an entry-level storage array. Starting with 3.84 TB of embedded flash capacity, you can scale your system with any combination of solid-state disks (SSDs), high-performance enterprise SAS HDDs, or low-cost midrange SAS HDDs. Capable of delivering up to 395,000 IOPS, the MSA 2062 also offers great value through the included all-inclusive software suite and 3.84 TB of flash capacity. It’s a truly simple and affordable flash storage that helps you achieve high performance while meeting challenging budgets.
HPE MSA 2062 Storage
HPE MSA 2062 Storage
1. | Power Switch | 5. | 12Gb SAS expansion port |
2. | Redundant Power and Cooling Module (AC or DC) | 6. | Controller A (Inverted) |
3. | Host connection ports (8/16Gb FC, 10/25GbE iSCSI, 1/10GBase-T, or 12Gb SAS depending on model) | 7. | Controller B |
4. | Ethernet management port |
HPE MSA 2062 Storage | |
Array | |
Access Type | Block |
Form Factor | 2U, SFF or LFF |
Number of controllers per array | 2 |
Number of host ports per array | 8 |
FC host connectivity | 8/16Gb |
iSCSI host connectivity | 10/25GbE (SFP)
1/10G Base-T (RJ-45) |
SAS host connectivity | 12Gb |
Cache, per array | |
Max Read cache per array | 8TB |
Data (read/write) cache + system memory per array | 24GB |
Pool Capacity | Two Pools with 1 PB each |
RAID Levels supported: | RAID 0*,1, 5, 6, 10, MSA-DP+
Notes: *Read Cache Only |
Enclosures | |
Expansion Drive Enclosures | 0-9 enclosures |
LFF/SFF array/enclosure mixing | Supported |
Maximum number of drives per array enclosure | 24 SFF or 12 LFF |
Maximum number of drives per drive enclosure | 24 SFF or 12 LFF |
Drive enclosure interface type | 12Gb SAS |
Drives | |
Maximum total HDDs per array | 240 SFF / 120 LFF |
Maximum total SSDs per array | 240 SFF / 120 LFF |
Max raw capacity per array enclosure | 172.8TB SFF / 203.84TB LFF |
Max raw capacity per drive enclosure | 184.32TB SFF / 240TB LFF |
Max raw capacity per array | 1831.68TB (All SFF) / 2363.84TB (All LFF) |
Drive Capacities | |
SFF SSDs | 960GB, 1.92TB, 3.84TB, 7.68TB |
LFF SSD | 1.92TB |
SFF HDDs | 15K: 900GB
10K: 600GB, 1.2TB, 1.8TB, 2.4TB |
LFF HDDs | 7.2K: 6TB, 8TB, 10TB, 12TB, 14TB, 16TB, 18TB, 20TB |
Software Features | |
Thin Technologies | Thin Provisioning, Space Reclamation, Thin Rebuild |
Tiering | Performance Tier, Standard Tier, Archive Tier |
Replication | Snapshots (512), Volume Copy, Remote Snaps |
Quality of Service | Virtual Tier Affinity |
Bundled/Integrated Licenses | Advanced Data Services LTU standard on MSA 2062
(preinstalled on the array) |
Maximum number of volumes per pool | 512 |
Maximum number of volumes per array | 1024 |
Maximum number of snapshots (included with array) | 64 |
Maximum number of snapshots (with Advanced Data Services
License) |
512 |
Maximum number of hosts | 512 |
Maximum number of initiators | 1024 |
Customer self-installable | Yes |
Customer self-repairable | Yes |
Customer self-upgradeable | Yes |
Health Check analytics | Yes |
Energy Star Certified | Yes |
MSA 2062 | |
Power requirements | |
Input Power Requirements (typical-running I/O)
SFF/LFF arrays |
120VAC 3.07A, 293-361 W; 220VAC 1.58A,289-352W |
Max Input Power | 100-240 VAC, 50/60 Hz., 4.38-2.17A; 48-60 VDC 10.4A/8.3A |
Heat Dissipation | 1766 BTU/hr |
Temperature and Humidity Ranges | |
Operating Temperature | ASHRAE A3 5°C to 40°C, -12°C DP & 8 to 24°C DP
(Derate maximum allowable dry-bulb temperature 1°C/175m above 900m) |
Shipping Temperature | -40°F to 158°F (-40°C to 70°C) |
Operating Humidity | Up to 85% RH |
Non-Operating Humidity | Up to 90% RH @ 30°C |
Physical | |
Height | 3.5 in (8.9 cm) |
Depth (Back of chassis ear to controller latch) | 20.0 in (50.8 cm) |
Depth (Front of chassis ear to back of cable bend) | 26.4 in (66.9 cm) |
Width (Chassis only) | 17.5 in (44.5 cm) |
Width (Chassis with bezel ear caps) | 19.0 in (48.3 cm) |
Weight LFF Enclosure | |
Chassis empty | 11 lb (5 kg) |
Controller enclosure (fully populated with FRUs and disks) | 71 lb (32 kg) |
Expansion enclosure (fully populated with FRUs and disks) | 62 lb (28 kg) |
Weight SFF Enclosure | |
Chassis empty | 11 lb (5 kg) |
Controller enclosure (fully populated with FRUs and disks) | 66 lb (30 kg) |
Expansion enclosure (fully populated with FRUs and disks) | 55 lb (25 kg) |
Acoustic Ratings | |
Sound Power | A weighted sound power LWAd – 8.3 B |
Sound Pressure | A weighted sound pressure LpAm – 74dBA |
Shock and Vibration | |
Shock, Operational | 5G, 11 ms |
Shock, Non-Operational | 15G, 10ms |
Vibration, Operational | 5-500Hz, 0.18 Grms |
Vibration, Non-Operational | x-axis (5-300Hz) 0.8 Grms
z-axis (5-300Hz) 1.2 Grms |
Altitude | |
Altitude, operating | 3000m (10,000 feet) |
Altitude, non-operating | 12,192m (40,000 feet) |
Configuration Information
MSA 2062 Storage Systems | ||
Description | SKU | |
HPE MSA 2062 16Gb Fibre Channel SFF Storage | R0Q80B | |
HPE MSA 2062 10GbE iSCSI SFF Storage | R0Q82B | |
HPE MSA 2062 12Gb SAS SFF Storage | R0Q84B | |
HPE MSA 2062 10GBASE-T iSCSI SFF Storage | R7J71B |
Jackson (verified owner) –
Very fast delivery.
Aiden (verified owner) –
Very fast delivery.