24 x GE Electrical Ports, 4 x 10GE SFP+ Ports

Condition: NOB

RMA Warranty

support team Girl Avatar

Expert Consultant Support

Solution Support ,More Discount.
Live Chat   |   Email
7*24h Online

Description

Business systems such as medical care, libraries, exhibition centers, websites and other gigabit access.
Highlight Features
  • Provides multiple network management methods,  achieving simple and easy network maintenance.
  • Provides open and programmable RGOS modular operating system. Basic functions are incorporated into the main version, and c ustom functions are released in app mode, ensuring stability of the basic functions.
  • Rectifies faults related to processes online in seconds, without interrupting network operation.
  • Supports Python that allows applications across platforms.
  • Upgrades and extends functions online to ensure nonstop services.
Hardware Specifications
Hardware Specifications RG-CS83-12GT4XS-P RG-CS83-24GT4XS RG-CS83-48GT4XS RG-CS83-24GT4XS-P RG-CS83-48GT4XS-P
Interface Specifications
Fixed ports 12 x 100M/1000M  BASE-T ports

4 x 1GE/10GE SFP+ ports

support PoE+

24 x 100M/1000M BASE-T ports

4 x 1GE/10GE SFP+ ports

48 x 100M/1000M BASE-T ports

4 x 1GE/10GE SFP+ ports

24 x 100M/1000M BASE-T ports

4 x 1GE/10GE SFP+ ports

support PoE+

48 x 100M/1000M BASE-T ports

4 x 1GE/10GE SFP+ ports

support PoE+

Fan module 1 x fixed fan module No fan 1 x fixed fan module 1 x fixed fan module 1 x fixed fan module
Power module 1 x fixed power module 1 x fixed power module 1 x fixed power module 1 x fixed power module 1 x fixed power module
Fixed management port 1 x console, and 1 x USB 2.0 port
System Specifications
Packet forwarding rate 78 Mpps 96 Mpps 132 Mpps 96 Mpps 132 Mpps
Switching capacity 104 Gbps 128 Gbps 176 Gbps 128 Gbps 176 Gbps
MAC address table size 16,000
ARP table size 4,000 4,000 4,000 4,000 4,000
Number of IPv4 unicast routes 6,000
Number of IPv4 multicast routes 1,000
Number of IPv6 unicast routes 2,000
Number of IPv6 multicast routes 750
Number of ACEs Ingress: 1,750

Egress: 800

Number of VSU members 4 4 4 4 4
Dimensions and Weight
Dimensions (W x D x H) 442 mm x 220 mm x 43.6mm (17.40 in. x 8.66 in. x 1.72 in.) 442 mm x 220 mm x 43.6mm (17.40 in. x 8.66 in. x 1.72 in.) 442 mm x 220 mm x 43.6mm (17.40 in. x 8.66 in. x 1.72 in.) 442 mm x 220 mm x 43.6mm (17.40 in. x 8.66 in. x 1.72 in.) 442 mm x 220 mm x 43.6mm (17.40 in. x 8.66 in. x 1.72 in.)
 Weight 3 kg (6.61 lbs) 3 kg (6.61 lbs) 3 kg (6.61 lbs) 3 kg (6.61 lbs) 3.75 kg (8.27 lbs)
CPU and Storage
CPU 1.0 GHz dual-core CPU 1.0 GHz dual-core CPU 1.0 GHz dual-core CPU 1.0 GHz dual-core CPU 1.0 GHz dual-core CPU
Flash memory 512 MB 512 MB 512 MB 512 MB 512 MB
BootROM 16 MB 16 MB 16 MB 16 MB 16 MB
SDRAM 1 GB 1 GB 1 GB 1 GB 1 GB
Data packet buffer 4 MB 4 MB 4 MB 4 MB 4 MB
Power and Consumption
Maximum power consumption < 35 W (non-PoE)

< 405 W (PoE full load)

< 25 W < 40 W < 35 W (non-PoE)

< 405 W (PoE full load)

< 52 W (non-PoE)

< 460 W (PoE full load)

Maximum output power 409 W

Maximum  PoE output :370W

25 W 40 W 409 W

Maximum  PoE output :370W

460 W

Maximum  PoE output :405W

Rated input voltage 100 V AC to 240 V AC 100 V AC to 240 V AC 100 V AC to 240 V AC 100 V AC to 240 V AC 100 V AC to 240 V AC
Maximum input voltage 90 V AC to 264 V AC, 50 Hz to 60 Hz 90 V AC to 264 V AC, 50 Hz to 60 Hz 90 V AC to 264 V AC, 50 Hz to 60 Hz 90 V AC to 264 V AC, 50 Hz to 60 Hz 90 V AC to 264 V AC, 50 Hz to 60 Hz
Environment and Reliability
MTBF 24.14 years 23.74 years 23.85 years 23.94 years 22.86 years
Primary airflow Front-to-right and left-to-right airflow
Operating temperature 0°C to 45°C (32°F to 113°F)
Storage temperature –40°C to +70°C (–40°F to +158°F)
Operating humidity 10% to 90% RH (non-condensing)
Storage humidity 5% to 95% RH (non-condensing)
Operating noise 27℃: < 35 dB < 20 dB 27℃: < 32 dB 27℃: < 35 dB 27℃: < 35 dB
Interface surge protection Power port: 6 kV(common mode)/8 kV (differential mode)

Communication port: 10 kV

Power port: 6 kV(common mode)/6 kV (differential mode)

Communication port: 10 kV

Power port: 6 kV(common mode)/6 kV (differential mode)

Communication port: 10 kV

Power port: 6 kV(common mode)/8 kV (differential mode)

Communication port: 10 kV

Power port: 6 kV(common mode)/8 kV (differential mode)

Communication port: 10 kV

 

Software Specifications

RG-CS83 Series
Feature Description
Ethernet switching Jumbo frame (maximum length: 9,216 bytes)
802.3az EEE
IEEE 802.1Q (4K VLANs)
Voice VLAN
Super-VLAN and private VLAN
MAC address-based VLAN, interface-based VLAN, protocol-based VLAN, and IP subnet-based VLAN
GVRP
Basic QinQ

Selective QinQ

STP, RSTP, and MSTP
ERPS (G.8032)
LLDP/LLDP-MED
IP service ARP
DHCP client, DHCP relay, and DHCP server
DHCP snooping
DNS
DHCPv6 client, DHCPv6 relay, and DHCPv6 server
DHCPv6 snooping
Neighbor Discovery (ND) and ND snooping
IP routing Static routing
RIP and RIPng
OSPFv2 and OSPFv3
IPv4 and IPv6 VRF
IPv4 and IPv6 PBR
Multicast IGMP v1/v2/v3, and IGMP proxy
IGMP v1/v2 snooping
PIM-DM, PIM-SM, and PIM-SSM
MSDP
MLD v1/v2
MLD snooping v1/v2
PIM-SMv6 and PIM-SSM v6
ACL and QoS Standard IP ACLs

Extended IP ACLs

Extended MAC ACLs

Time-based ACLs

Expert-level ACLs

ACL80

IPv6 ACL

ACL redirection
Traffic rate limiting on an interface
Congestion management: RR, SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ
Congestion avoidance: tail drop
802.1p/DSCP/ToS traffic classification

Eight priority queues per interface

Security Multiple AAA modes
RADIUS and TACAS+
Interface-based and MAC address-based 802.1x authentication
Web authentication
HTTPS
SSHv1 and SSHv2
Global IP-MAC binding
Port isolation and port security
IP source guard
SAVI
CPP and NFPP
Reliability REUP, RLDP, DLDP
IPv4 VRRP v2/v3 and IPv6 VRRP
BFD
Link tracing, fault notification, and remote loopback based on 802.3ah (EFM)
Hot swapping of power modules and cables
Fan speed adjustment

Fan fault alarm

Device virtualization Virtual Switching Unit (VSU)
NMS and maintenance SPAN, RSPAN
sFlow
NTP and SNTP
FTP and TFTP
SNMP v1/v2/v3
RMON (1, 2, 3, 9)
NETCONF
CWMP (TR-069)
gRPC
Cloud and SON
PoE RG-CS83-12GT4XS-P, RG-CS83-24GT4XS-P, and RG-CS83-48GT4XS-P:

IEEE 802.3af and 802.3at

Warm start

Interface priority

Order Information

Order switches, expansion modules, power supply modules, and other components as needed. Before ordering an expansion module or power supply module, please contact our online customer service team for the latest support information about the module.

Model Description
RG-CS83-12GT4XS-P 12 x 10M/100M/1000M electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports, PoE power supply, a maximum of 370 W PoE output, and built-in power module
RG-CS83-24GT4XS 24 x 10M/100M/1000M electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports, and built-in power module
RG-CS83-48GT4XS 48 x 10M/100M/1000M electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports, and built-in power module
RG-CS83-24GT4XS-P 24 x 10M/100M/1000M electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports, PoE power supply, a maximum of 370 W PoE output, and built-in power module
RG-CS83-48GT4XS-P 48 x 10M/100M/1000M electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports, PoE power supply, a maximum of 405 W PoE output, and built-in power module
Mini-GBIC-GT 1000BASE-GT mini GBIC module
MINI-GBIC-SX-MM850 Single-port 1000BASE-SX mini GBIC module (LC connector)
MINI-GBIC-LX-SM1310 Single-port 1000BASE-LX mini GBIC module (LC connector)
MINI-GBIC-LH40-SM1310 Single-port 1000BASE-LH mini GBIC module (LC connector), supporting a transmission distance of 40 km (24.85 miles)
MINI-GBIC-ZX50-SM1550 Single-port 1000BASE-ZX mini GBIC module (LC connector), supporting a transmission distance of 50 km (24.85 miles)
MINI-GBIC-ZX80-SM1550 Single-port 1000BASE-ZX mini GBIC module (LC connector), supporting a transmission distance of 80 km (24.85 miles)
MINI-GBIC-ZX100-SM1550 1000BASE-ZX mini GBIC module, supporting a transmission distance of 100 km (62.14 miles)
XG-SFP-SR-MM850 10GE LC module (62.5/125 μm: 33 m (108.27 ft.); 50/125 μm: 66 m (216.54 ft.); transmit for 300 m (984.25 ft.) when modal bandwidth is 2000 MHz * km), applicable to SFP+ ports
XG-SFP-LR-SM1310 10GE LC interface module (1310 nm), 10 km (6.21 miles), applicable to SFP+ ports
XG-SFP-ER-SM1550 10GE LC interface module (1550 nm), 40 km (24.85 miles), applicable to SFP+ ports
XG-SFP-AOC1M 10GE SFP+ fiber-optic cable, 1 m (3.28 ft.), including one cable and two interface modules
XG-SFP-AOC3M 10GE SFP+ fiber-optic cable, 3 m (3.28 ft.), including one cable and two interface modules
XG-SFP-AOC5M 10GE SFP+ fiber-optic cable, 5 m (3.28 ft.), including one cable and two interface modules

 

1 review for RG-CS83-24GT4XS

  1. Mason (verified owner)

    Good service.

    1 product
Add a review

Your email address will not be published. Required fields are marked *

Good quality.The product is firmly packed.Good service.Very well worth the money.Very fast delivery.