Description
Full gigabit ports and flexible and scalable 10GE uplink data exchange capability, coping with data center problems such as massive device quantity, high cost, and traffic burst
- 48 x 10/100/1000 Mbps electrical ports with auto-negotiation and 4 x 10GE SFP+ ports for flexible networking
- Cross-device link aggregation (de-stacking/M-LAG/VSU), securing key service continuity, flexible networking, and high reliability
- Hardware-level redundancy, ensuring service consistency and network stability
- Multiple network security policies and real-time monitoring, safeguarding network robustness
Hardware Specifications
System Specifications | RG-S6000C-48GT4XS-E |
Fixed ports | 48 x 10/100/1000 Mbps electrical ports with auto-negotiation, 4 x 10GE SFP+ ports |
Expansion modules | One line card slot, supporting the 4-port 10GE SFP+ module
Two power module slots One fan module slot (front-to-rear airflow) |
Switching capacity | 256Gbps |
Packet forwarding rate | 192Mpps |
802.1Q VLAN | 4094 |
Dimensions | RG-S6000C-48GT4XS-E |
Dimensions (W x D x H) | 440 mm x 300 mm x 44 mm (17.32 in. x 11.81 in. x 1.73 in.) |
Weight | 4.8 kg (10.58 lbs., including two power modules and one fan modules) |
Power Supply and Consumption | RG-S6000C-48GT4XS-E |
Input power requirement | AC input:
Rated voltage range: 100 V AC to 240 V AC Max. voltage range: 90 V AC to 264 V AC Frequency: 50 Hz to 60 Hz HVDC input: Rated voltage range: 120 V DC to 340 V DC Max. voltage range: 110 V DC to 380 V DC |
Max. power consumption | 60 W |
Fan | Fan speed regulating and fault alarming |
Temperature alarm | Supported |
Environment and Reliability | RG-S6000C-48GT4XS-E |
Temperature | Operating temperature: 0°C to 50°C (32°F to 122°F) Storage temperature: –40°C to 70°C (–40°F to 158°F) |
Humidity | Operating humidity: 10% to 90% RH Storage humidity: 5% to 95% RH |
Working altitude | Operating altitude: up to 5000 m (16,404.20 ft.) Storage altitude: up to 5000 m (16,404.20 ft.) |
Software Specifications
Software Specifications | RG-S6000C-48GT4XS-E | |||||||||
Next-generation data center features (*) | Cloud computing and virtualization features:
(*) VEPA (*) VM discovery and automatic migration of security policies |
|||||||||
L2 features | Ethernet(Frame format: Ethernet II/10GE SFP+ port, supporting 1GE optical module (including 1GE SFP module and 1GE SFP-GT module)/Optical module information display, fault alarm, and diagnosis parameter measurement (OSPF+/SFP+/SFP)/Flow control)、IEEE802.1d STP、IEEE802.1w RSTP、MSTP、STP、Aggregate interface、Storm suppression、Mirroring、MMU、VLAN、Basic QinQ、Selective QinQ、MAC address、RLDP、LLDP、Layer 2 protocol tunnel、REUP、G.8032 (Standard RERP, compatible with other G.8032 standards)、Cable diagnosis、IGMP snooping、MLD snooping | |||||||||
IPv4 features | Ping、Traceroute、ECMP、ECMP for static recursive routing、Unicast Reverse Path Forwarding (URPF)、IPIP、IPv6/IPv4 over IPv4 GRE tunnel、IPv4 VRF | |||||||||
VLAN | 4K IEEE 802.1Q VLANs
Port-based VLAN MAC-based VLAN Protocol-based VLAN Private VLAN Voice VLAN Private VLAN IP subnet-based VLAN GVRP |
|||||||||
QinQ | Basic QinQ
Selective QinQ N:1 and 1:1 VLAN switching |
|||||||||
Link aggregation | LACP (IEEE 802.3ad) | |||||||||
SPAN | N:1 mirroring
1:N mirroring Traffic-based mirroring |
|||||||||
Spanning Tree Protocol | STP, RSTP, and MSTP | |||||||||
DHCP | DHCP server
DHCP client DHCP snooping DHCP relay IPv6 DHCP snooping IPv6 DHCP client IPv6 DHCP relay |
|||||||||
Basic IPv6 protocols | IPv6 addressing, Neighbor Discovery (ND), ND Snooping, ICMPv6, Stateless Auto Configuration, Path MTU Discovery | |||||||||
IP routing | Static routing
RIP, RIPng OSPF, OSPFv3, IS-IS, IS-IS v6 BGP, BGP4+ Equal-cost multi-path routing (ECMP) Packet-based and traffic-based load balancing Multi-VPN-Instance CE (MCE) |
|||||||||
Multicast | IGMPv1/v2/v3 and IGMP proxy
IGMPv1/v2/v3 snooping IGMP filtering, IGMP fast leave PIM-DM, PIM-SM, PIM-SSM MLD snooping, MLD PIM for IPv6 MSDP |
|||||||||
MPLS | MPLS forwarding、LDP、LSP | |||||||||
IPv6 tunneling | Manually configured tunnel, automatic tunnel, ISATAP, IPv4 over IPv6, GRE tunnel, and other tunneling technologies | |||||||||
ACL | The following flexible and diversified hardware ACLs are available:
Standard IP ACL (IP-based hardware ACL) Extended IP ACL (hardware ACL based on the IP address or TCP/UDP port ID) Extended MAC ACL (hardware ACL based on the source MAC address, destination MAC address, and optional Ethernet type) Time-based ACL Expert-level ACL (hardware ACL based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port ID, protocol type, and time) ACL80 IPv6 ACL |
|||||||||
QoS | Port traffic identification
Port traffic rate limiting 802.1p/DSCP/ToS traffic classification Eight priority queues per port SP, WRR, DRR, SP+WFQ, SP+WRR, SP+DRR, and RED/WRED queue scheduling |
|||||||||
Security features | 3-tuple binding (IP address, MAC address, and port)
3-tuple binding (IPv6 address, MAC address, and port) MAC address filtering Port- and MAC-based 802.1x authentication MAC Bypass Authentication (MAB) Portal authentication and Portal 2.0 authentication ARP check Dynamic ARP inspection (DAI) ARP rate limiting ARP spoofing prevention Broadcast storm suppression Hierarchical management and password protection RADIUS and TACAS+ AAA (IPv4/IPv6) for device login management SSH and SSHv2.0 BPDU Guard IP source guard CPP and NFPP Port protection |
|||||||||
Management features | SNMPv1/v2c/v3, CLI (Telnet/Console), RMON (1,2,4,9), SSH, Syslog, NTP/SNTP, SNMP over IPv6, IPv6 MIB support for SNMP, SSHv6, Telnet v6, FTP/TFTPv6, DNSv6, NTP for v6, Traceroute v6
sFLOW using the random sampling technology to conduct flow information sampling on the switch traffic |
|||||||||
High reliability | VSU GR for RIP, GR for OSPF, GR for BGP, and GR for other routing protocols BFD ERPS (G.8032) REUP RLDP 1+1 power redundancy One modular fan module with front-to-rear airflow 2+1 fan redundancy Hot swapping of power modules |
|||||||||
Energy Efficient Ethernet (EEE) | IEEE 802.3az-compliant EEE: When EEE is enabled, power consumption of ports is significantly reduced. | |||||||||
Compatibility with cloud platform |
(Names not listed in order) |
Safety and Regulatory Compliance
Specifications | RG-S6000C-48GT4XS-E |
Safety | ● IEC 62368-1
● EN 62368-1 ● EN IEC 62368-1 ● BS EN IEC 62368-1 ● UL 62368-1 ● CSA C22.2#62368-1 ● UL60950-1 ● CAN/CSA C22.2 NO. 60950-1-07 ● GB 4943.1 |
Electromagnetic Compatibility (EMC) | ● EN 55032
● EN 61000-3-3 ● EN IEC 61000-3-2 ● EN 55035 ● EN 300 386 ● ETSI EN 300 386 ● ICES-003 Issue 7 ● ANSI C63.4-2014 ● FCC CFR Title 47, Part 15, Subpart B ● ICES-003 Issue 6 ● GB/T 9254.1 |
Environment | ● 2011/65/EU EN 50581
● 2012/19/EU EN 50419 ● (EC) No.1907/2006 ● GB/T 26572 |
*For more country-specific regulatory information and approvals, contact your local sales agency.
Order Information
Chassis and Modules
Model | Description |
RG-S6000C-48GT4XS-E | Data center switch, 48 x 10/100/1000 Mbps electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports,1 x expansion module slot, 1 x modular fan M6000E-FAN-F, 2 x modular power module slots (at least one power module needs to be purchased). |
RG-PA70I | AC power module |
M6000E-FAN-F | Fan module (front-to-rear airflow) |
M6000E-04XS | 4-port 10GE SFP+ module (LC connector) for the RG-S6000C-48GT4XS-E switch |
10GBASE Series Optical Modules
Model | Description |
XG-SFP-SR-MM850 | 10G SR module, SFP+ form factor, Duplex LC, 300 m (984.25 ft.) over MMF |
XG-SFP-LR-SM1310 | 10G LR module, SFP+ form factor, Duplex LC, 10 km ((32,808.40 ft.) over SMF |
XG-SFP-ER-SM1550 | 10G ER module, SFP+ form factor, Duplex LC, 40 km (131,233.60 ft.) over SMF |
XG-SFP-ZR-SM1550 | 10G ZR module, SFP+ form factor, Duplex LC, 80 km (262,467.19 ft.) over SMF |
XG-SR-MM850 | 10G SR module, SFP+ form factor, Duplex LC, 300 m (984.25 ft.) over MMF |
XG-LR-SM1310 | 10G LR module, SFP+ form factor, Duplex LC, 10 km ((32,808.40 ft.) over SMF |
XG-SFP-AOC1M | 10G SFP+ AOC cable, 1 m (3.28 ft.) |
XG-SFP-AOC3M | 10G SFP+ AOC cable, 3 m (9.84 ft.) |
XG-SFP-AOC5M | 10G SFP+ AOC cable, 5 m (16.40 ft.) |
1000BASE Series Optical Modules
Model | Description |
MINI-GBIC-SX-MM850 | 1G SR module, SFP form factor, Duplex LC, 550 m (1,804.46 ft.) over MMF |
MINI-GBIC-LX-SM1310 | 1G LX module, SFP form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF |
MINI-GBIC-LH40-SM1310 | 1G LH module, SFP form factor, Duplex LC, 40 km (131,233.60 ft.) over SMF |
MINI-GBIC-ZX80-SM1550 | 1G ZX module, SFP form factor, Duplex LC, 80 km (262,467.19 ft.) over SMF |
GE-SFP-LH40-SM1310-BIDI | 1G LH module, SFP form factor, BIDI LC, 40 km (131,233.60 ft.) over SMF |
GE-SFP-LX20-SM1310-BIDI | 1G LX module, SFP form factor, BIDI LC, 20 km (65,616.80 ft.) over SMF |
GE-SFP-LX20-SM1550-BIDI | 1G LX module, SFP form factor, BIDI LC, 20 km (65,616.80 ft.) over SMF |
1000BASE Series Electrical Modules
Model | Description | |
Mini-GBIC-GT | 1G SFP copper module, SFP form factor, RJ45, 100 m (328.08 ft.) over Cat 5e/6/6a |