four service slots, 25GE/40GE/100GE line cards

Condition: NOB

RMA Warranty

support team Girl Avatar

Expert Consultant Support

Solution Support ,More Discount.
Live Chat   |   Email
7*24h Online

Description

M-LAG/VSU/de-stacking for higher availability, PFC/ECN-based lossless RDMA network with high performance

Highlight Features
  • 96 x 25GE ports and 8 x 100GE ports, 32 x 100GE ports, or 64 x 40GE ports housed in a 2 RU enclosure for flexible networking
  • Cross-device link aggregation (De-stacking/M-LAG/VSU), device-level redundancy, flexible networking, and high reliability
  • VXLAN tunneling technology, achieving unlimited data transmission and flexible resource allocation and scheduling
  • Lossless Ethernet, ensuring zero packet loss during RDMA E2E communication
  • Telemetry/gRPC/sFlow/SPAN-based network monitoring and automated O&M, making management simple and efficient

 

Hardware Specifications

System Specifications RG-S6510-4C
Ports 25GE, 40GE, and 100GE ports
Slots 4
Expansion Modules M6500-24VS2CQ, M6500-08CQ, M6500-16QXS
Expansion Module Slots Power supply module slots

Fan module slots

Management Port One management port, one console port, and one USB port, compliant with the USB2.0 standard
Switching Capacity 6.4 Tbps
Packet Forwarding Rate 2030 Mpps
802.1Q VLAN 4094
Dimensions and Weight RG-S6510-4C
Dimensions
(W × D × H)
442 mm × 520 mm × 86 mm

(2 RU)

Weight About 19 kg (including power supply modules and fan modules)
Power Supply and Consumption RG-S6510-4C
AC Rated voltage range: 100 VAC to 240 VAC, 50 Hz to 60 Hz

Maximum voltage range: 90 VAC to 264 VAC, 50 Hz to 60 Hz

Rated input current: 5 A to 10 A

High-voltage DC Input voltage range: 192 VDC to 288 VDC

Input current range: < 4.5 A

Maximum Power Consumption 650 W
Environment and Reliability RG-S6510-4C
Operating Temperature 0ºC to 40ºC (32ºF to 104ºF)
Storage temperature -40 °C to 70 °C (-40 °F to 158 °F)
Operating Humidity 10% to 90% RH (Non-condensing)
Storage humidity 5% to 95% RH (non-condensing)
Working altitude Operating altitude: up to 5000 m (16,404.20 ft.)

Storage altitude: up to 5000 m (16,404.20 ft.)

Software Specifications

Software Specifications RG-S6510-4C
Device virtualization Virtual Switching Unit 3.0
L2 Protocols IEEE802.3ad (Link Aggregation Control Protocol), IEEE802.1p, IEEE802.1Q, IEEE802.1D (STP), IEEE802.1w (RSTP), IEEE802.1s (MSTP), IGMP Snooping, MLD Snooping, Jumbo Frame (9 KB), IEEE802.1ad (QinQ and selective QinQ), GVRP
L3 Protocols (IPv4) BGP4, OSPFv2, RIPv1, RIPv2, MBGP, LPM Routing, Policy-based Routing (PBR), Route-policy, Equal-Cost Multi-Path Routing (ECMP), WCMP, VRRP, IGMP v1/v2/v3, PIM-SSM/SM/DM, MSDP, Any-RP
IPv6 Basic Protocols Neighbor Discovery, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB support for SNMP, VRRP for IPv6, IPv6 QoS
IPv6 Features Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+, MLDv1/v2, PIM-SMv6, manual tunnel, automatic tunnel, IPv4 over IPv6 tunnel, and ISATAP tunnel
Data Center Features VXLAN routing and VXLAN bridging

EVPN VXLAN

IPv6 VXLAN over IPv4

PFC, ECN, and other data center features

RDMA

M-LAG

OpenFlow 1.3

Visualization gRPC

sFLOW sampling

INT

ACL Standard IP-based ACL、Extended MAC-based ACL、Extended IP-bsaed ACL、Expert-level ACL、ACL 80、IPv6 ACL、ACL Logging、Ingress/Egress ACLs、ACL Counter (Ingress and egress counters are supported in interface or global configuration modes)、ACL Re-marking、Global ACL、ACL-based Redirection、Displaying ACL Resources、Processing First Packet of TCP Handshake When Binding the ACL to Restrict SIP、Matching Against 5-Tuple of Pass-by VXLAN Inner IP Packets、The expert-level ACL supports matching the IP flag and DSCP fields of VXLAN inner packets
QoS Mapping of IEEE 802.1p, DSCP, and ToS priorities
ACL-based traffic classification
Priority marking/remarking
Multiple queue scheduling mechanisms, including SP, WRR, DRR, SP+WRR, and SP+DRR
Congestion avoidance mechanisms such as WRED and tail discarding
Virtualization Virtual Switching Unit
Cache Management Cache status monitoring and management, and identification of burst traffic
HA Design GR for RIP/OSPF/BGP, BFD, REUP dual-link fast switching and RLDP unidirectional link detection, 1+1 power redundancy, and fan redundancy, and hot swapping for all cards and power supply modules
Security Features Network Foundation Protection Policy (NFPP), CPP, DDoS attack defense, illegitimate data packet detection, data encryption, source IP spoofing prevention, IP scanning prevention, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, plaintext-based and MD5 ciphertext-based authentication for OSPF, RIPv2, and BGPv4 packets, telnet login and password mechanisms for restricted IP addresses, uRPF, broadcast packet suppression, DHCP Snooping, gateway ARP spoofing prevention, and ARP check
Management Mode SNMP v1/v2/v3, Netconf, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP clock, Syslog, SPAN/RSPAN, Telemetry, ZTP, Python, fan and power supply alarm, and temperature alarm
Other Protocols DHCP Client, DHCP Relay, DHCP Server, DNS Client, UDP relay, ARP Proxy, and Syslog

 

Safety and Regulatory Compliance

Specification RG-S6510-4C
Safety ●     NM EN 62368-1

●     NM CEI62368-1

●     IEC 62368-1

●     EN 62368-1

●     BS EN 62368-1

●     UL 62368-1

●     CSA C22.2#62368-1

●     GB 4943.1

Electromagnetic Compatibility (EMC) ●     GB9254 CLASS A EN 61000-4-2

●     EN 61000-4-3

●     EN 61000-4-4

●     EN 61000-4-5

●     EN 61000-4-6

●     EN 61000-4-11

●     EN 55032

●     EN 55035

●     EN 61000-3-2

●     EN 61000-3-3

●     EN IEC 61000-3-2

●     EN IEC 61000-3-3

●     EN 300 386

●     ETSI EN 300 386

●     NM EN 55035

●     NM EN 61000-3-2

●     NM EN 61000-3-3

●     BS EN 55032

●     BS EN 55035

●     BS EN 61000-3-2

●     BS EN 61000-3-3

●     CNS 13438

●     FCC CFR Title 47, Part 15, Subpart B

●     ANSI C63.4-2014

●     ICES-003 Issue 7

●     GB/T 9254.1

Environment ●     2011/65/EU EN 50581

●     2012/19/EU EN 50419

●     (EC) No.1907/2006

●     GB/T 26572

*For more country-specific regulatory information and approvals, contact your local sales agency.

Order Information

The configuration procedure for RG-S6510-4C series switches is as follows:

● Select the switch, fan, and power supply modules.

● Select expansionmodules based on port

● Select optical transceivers.

Chassis, Fan, and Power Supply Modules

Product Model Description
RG-S6510-4C Four expansion module slots, supporting hot swapping.
Two power supply module slots and three fan module slots
The power supply model is RG-PA800I-F, and the fan model is M6500-FAN-F.
RG-PA800I-F Power supply module, supporting 1+1 redundancy, hot swapping, and front-to-rear ventilation design
M6500-FAN-F Fan module, supporting 2+1 redundancy, hot swapping, and front-to-rear ventilation design

 

Expansion Modules

Product Model Description
M6500-08CQ Eight QSFP28 ports

The QSFP28 port supports a speed of 40 Gbps/100 Gbps.

M6500-24VS2CQ 24 25GE SFP28 ports and two QSFP28 ports

SFP28 supports a speed of 10G/25G rates.

The QSFP28 port supports a speed of 40 Gbps/100 Gbps. One QSFP port can be split into four 10GE or 25GE ports.

M6500-16QXS 16 QSFP ports
The QSFP28 port supports a speed of 40 Gbps.

 

100GBASE Series Optical Modules

Product Model Description
100G-QSFP-SR-MM850 100G SR module, QSFP28 form factor, MPO, 850 nm, 100 m (328.08 ft.) over MMF
100G-QSFP-LR4-SM1310 100G LR4 module, QSFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF
100G-QSFP-iLR4-SM1310 100G iLR4 module, QSFP28 form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF
100G-QSFP-ER4-SM1310 100G ER4 module, QSFP28 form factor, Duplex LC, 1310 nm, 40 km (131,233.59 ft.) over SMF
100G-AOC-5M 100G QSFP28 AOC cable, 5 m (16.40 ft.)
100G-AOC-10M 100G QSFP28 AOC cable, 10 m (32.81 ft.)

 

40GBASE Series Optical Modules

Product Model Description
40G-QSFP-SR-MM850 40G SR module, QSFP+ form factor, MPO, 150 m (492.13 ft.) over MMF
40G-QSFP-LR4-SM1310 40G LR4 module, QSFP+ form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF
40G-QSFP-LSR-MM850 40G LSR module, QSFP+ form factor, MPO, 400 m (1,312.34 ft.) over MMF
40G-QSFP-iLR4-SM1310 40G iLR4 module, QSFP+ form factor, Duplex LC, 2 km (6,561.68 ft.) over SMF
40G-QSFP-LX4-SM1310 40G LX4 module, QSFP+ form factor, Duplex LC connector, 150 m (492.13 ft.) over OM3/OM4 MMF, or 2 km (6,561.68 ft.) over SMF
40G-AOC-30M 40G QSFP+ AOC cable, 30 m (98.43 ft.)
40G-AOC-5M 40G QSFP+ AOC cable, 5 m (16.40 ft.)

 

25GBASE Series Optical Modules

Product Model Description
VG-SFP-LR-SM1310 25G LR module, SFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF
VG-SFP-AOC5M 25G SFP28 AOC cable, 5 m (16.40 ft.)

 

10GBASE Series Optical Modules

Product Model Description
XG-LR-SM1310 10G LR module, SFP+ form factor, Duplex LC, 10 km ((32,808.40 ft.) over SMF
XG-SFP-ER-SM1550 10G ER module, SFP+ form factor, Duplex LC, 40 km (131,233.60 ft.) over SMF
XG-SFP-LR-SM1310 10G LR module, SFP+ form factor, Duplex LC, 10 km ((32,808.40 ft.) over SMF
XG-SFP-SR-MM850 10G SR module, SFP+ form factor, Duplex LC, 300 m (984.25 ft.) over MMF
XG-SFP-ZR-SM1550 10G ZR module, SFP+ form factor, Duplex LC, 80 km (262,467.19 ft.) over SMF
XG-SR-MM850 10G SR module, SFP+ form factor, Duplex LC, 300 m (984.25 ft.) over MMF
XG-SFP-AOC1M 10G SFP+ AOC cable, 1 m (3.28 ft.)
XG-SFP-AOC3M 10G SFP+ AOC cable, 3 m (9.84 ft.)
XG-SFP-AOC5M 10G SFP+ AOC cable, 5 m (16.40 ft.)

1000BASE Series Optical Modules

Product Model Description
GE-SFP-LH40-SM1310-BIDI 1G LH module, SFP form factor, BIDI LC, 40 km (131,233.60 ft.) over SMF
GE-SFP-LX20-SM1310-BIDI 1G LX module, SFP form factor, BIDI LC, 20 km (65,616.80 ft.) over SMF
GE-SFP-LX20-SM1550-BIDI 1G LX module, SFP form factor, BIDI LC, 20 km (65,616.80 ft.) over SMF
MINI-GBIC-LH40-SM1310 1G LH module, SFP form factor, Duplex LC, 40 km (131,233.60 ft.) over SMF
MINI-GBIC-LX-SM1310 1G LX module, SFP form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF
MINI-GBIC-SX-MM850 1G SR module, SFP form factor, Duplex LC, 550 m (1,804.46 ft.) over MMF
MINI-GBIC-ZX80-SM1550 1G ZX module, SFP form factor, Duplex LC, 80 km (262,467.19 ft.) over SMF

1000BASE Series Electrical Modules

Product Model Description
Mini-GBIC-GT(F) 1G SFP copper module, SFP form factor, RJ45, 100 m (328.08 ft.) over Cat 5e/6/6a
Mini-GBIC-GT 1G SFP copper module, SFP form factor, RJ45, 100 m (328.08 ft.) over Cat 5e/6/6a

1 review for RG-S6510-4C

  1. Jackson (verified owner)

    Good service.

    1 product
Add a review

Your email address will not be published. Required fields are marked *

Good quality.The product is firmly packed.Good service.Very well worth the money.Very fast delivery.