Description
S110-8LP2ST technical indicators
Project | Describe |
---|---|
Dimensions (W x D x H, excluding packaging) [mm] | Basic dimensions (depth is the distance excluding the protruding structural parts of the front and rear panels): 210.0mm×130.0mm×35mm
Maximum size (depth is the maximum distance from the protruding port on the front panel to the protruding structure on the rear panel): 210.0mm×131.7mm×36.5mm |
Dimensions (W x D x H, including packaging) [mm] | 280.0mm×270.0mm×55.0mm |
Chassis height [U] | 0.8U |
Chassis material | PC+ABS |
Weight (excluding packaging materials) [kg] | 0.61kg |
Weight (including packaging) [kg] | 0.85kg |
Typical power consumption [W] | 8W |
Typical heat dissipation value [BTU/hour] | 27.30BTU/hour |
Maximum power consumption [W] | Without PoE: 8.4W
PoE full load: 70W (PoE: 54W) |
Maximum heat dissipation value [BTU/hour] | Without PoE: 28.66
PoE full load: 238.85 |
Static power consumption [W] | 3W |
MTBF [years] | 85.44years |
MTTR [hours] | 2hours |
Availability | > 0.99999 |
Noise at room temperature (sound power) [dB(A)] | No fan, silent, <30 |
Noise at normal temperature (sound pressure) [dB(A)] | No fan, silent, <20 |
Number of card slots | 0 |
Number of power supply slots | 0 |
Number of fan modules | 0 |
Switching capacity | If you need this specification, please check the product brochure or contact the product salesperson to obtain it. |
Packet forwarding rate | If you need this specification, please check the product brochure or contact the product salesperson to obtain it. |
Operating mode | Standard mode, port isolation, flow control off |
Number of MAC addresses | 2K |
Power redundancy | not support |
Long-term working environment temperature [°C] | 0°C~+40°C (0m~1800m above sea level) |
Operating environment temperature change limit [°C] | 1800 m to 5000 m: The maximum temperature specification decreases by 1°C every time the altitude increases by 220 m. |
Storage temperature [°C] | -40°C~+70°C |
Long-term working environment relative humidity [RH] | 5%RH~95%RH, non-condensing |
Long-term working altitude [m] | 0m~5000m |
Storage altitude [m] | 0m~5000m |
Power supply type | Power Adapter |
Rated input voltage [V] | Power adapter input: 100V AC ~ 240V AC; 50/60Hz
Power adapter output: 54V DC |
Input voltage range[V] | Power adapter input: 90V AC ~ 264V AC; 47Hz ~ 63Hz |
Maximum input current [A] | 1.17A |
Memory | – |
Flash | – |
Console Interface Type | not support |
Eth management network port type | not support |
USB interface | not support |
Real-time Clock (RTC) | not support |
RPS Input | not support |
Business port lightning protection [kV] | Common mode ±4kV |
Power port lightning protection [kV] | Differential mode ±2kV, common mode ±4kV |
Triple protection (dustproof/waterproof) | IP20 |
Fan Type | Fanless |
Cooling method | Natural cooling |
Airflow direction | – |
PoE Function | support |
certified product | Support EMC certification
Support safety certification Support production certification |