ITMall,Your IT Global Procurement Service Expert
CE8865-4C
Бренд Huawei
4.9Проверено

CE8865-4C

Model (MPN)
CE8865-4C
Condition
Factory Sealed
Original Packaging (NIB)
Нет в наличии

CE8865-4C Mainframe (With 4 Subcard Slots, Without Fan and Power Modules)

Объемные и рамочные цены

Только B2B
КоличествоЦена за единицуПримерная экономия
1 Единица$272.20-
2 - 9 ЕдиницыЗапросить цену5 - 10%
10+ / ПроектРамочное соответствие Доступ Уровня 1
Доступна глобальная рамочная поддержкаПолучить скидку
Ваша цена
Call for Pricing
Volume discounts available
Availability Нет в наличии

Need configuration help?

Our CCIE certified engineers can help you verify compatibility.

Безопасная оплата
VISA
Pay
WIRE

Fast Dispatch

Global logistics network aiming for same-day handover.

48hrs
Avg. Shipping
99%
On-Time

Guaranteed Quality

Every unit undergoes rigorous 38-point inspection test.

3Year
Warranty
0.1%
RMA Rate

Global Reach

Trusted by enterprise clients across 6 continents.

85+
Countries
20k+
Clients

Expert Support

Certified network engineers ready to assist with configuration.

24/7
Assistance
CCIE
Certified

Обзор

A series of high port density switches, CloudEngine 8800 brings a combination of both high performance and low latency to cloud-oriented data center networks and high-end campus networks alike. Additionally, the series supports an extensive range of data center features, Software-Defined Networking (SDN) capabilities, and high performance stacking technologies. With 10, 25, 40, 100, 200, and 400 GE ports, as well as flexible plug-in cards, CloudEngine 8800 is well suited for both the core and aggregation layers. The series is also compatible with CloudEngine 16800, 12800, 6800, and 5800 series switches, helping enterprises build networks that are scalable, simplified, open — and secure.

Basic Information
Description CE8865-4C Mainframe (With 4 Subcard Slots, Without Fan and Power Modules)
Part Number 02355RTA
Model CE8865-4C
First supported version V300R023C10
Other part numbers 02355RTB (CE8865-4C Mainframe (With 4 Subcard Slots, 2*AC Power Modules, 3*Fans, Port-side Intake))
02355RTC (CE8865-4C Mainframe (With 4 Subcard Slots, 2*AC Power Modules, 3*Fans, Port-side Exhaust))
02356FKL (CE8865-4C mainframe with license bundle(With 4 Subcard Slots, 2*AC Power Modules, 3*Fans, Port-side Intake, Software license))
02356FKP (CE8865-4C mainframe with license bundle(With 4 Subcard Slots, 2*AC Power Modules, 3*Fans, Port-side Exhaust, Software license))
Short Name CE8865
Technical Specifications
Dimensions with packaging (H x W x D) [mm (in.)] 280 mm x 875 mm x 665 mm (11.02 in. x 34.45 in. x 26.18 in.)
Dimensions without packaging (H x W x D) [mm (in.)] – Basic dimensions (the depth excludes the parts protruding from the body): 88.1 mm x 442.0 mm x 600.0 mm (3.47 in. x 17.40 in. x 23.62 in.)
– Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 88.1 mm x 442.0 mm x 640.0 mm (3.47 in. x 17.40 in. x 25.20 in.)
Weight without packaging [kg (lb)] 12.76 kg (28.13 lb) (with two power module filler panels and three fan module filler panels but no power modules, fan modules, cards, and card filler panels)
15.48 kg (34.13 lb) (with four card filler panels, two power module filler panels, and three fan module filler panels but no power modules, fan modules, and cards)
Weight without packaging (full configuration) [kg (lb)] 16.54 kg (36.46 lb) (with two power modules and three fan modules, but no cards and card filler panels)
19.26 kg (42.46 lb) (with two power modules, three fan modules, and four card filler panels, but no cards)
Weight with packaging [kg (lb)] 21.3 kg (46.96 lb) (with two power module filler panels and three fan module filler panels but no power modules, fan modules, cards, and card filler panels)
24.02 kg (52.96 lb) (with four card filler panels, two power module filler panels, and three fan module filler panels but no power modules, fan modules, and cards)
Weight with packaging (full configuration) [kg (lb)] 25.08 kg (55.29 lb) (with two power modules and three fan modules, but no cards and card filler panels)
27.8 kg (61.29 lb) (with two power modules, three fan modules, and four card filler panels, but no cards)
Chassis height [U] 2
Installation Type Cabinet installation
Switching capacity To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel.
CPU 16-core, 2 GHz
Memory DRAM: 8 GB
NOR Flash 64 MB x 2
SSD Flash 4GB SSD
USB It can be used for log backup and USB-based deployment.
This function is reserved.
Power supply mode AC,DC,HVDC
Console port RJ45
Downlink Service interface For details, see the port description of each card.
Uplink Service interface For details, see the port description of each card.
Service port supporting the stack function Reserved function. This function is not enabled.
RTC Supported
Typical power consumption [W] Configured with four CE88-D16CQ-H cards:
– 650 W (100% traffic load, copper cables on 32 x 100GE ports, normal temperature, dual AC power modules)
– 728 W (100% traffic load, short-distance optical modules on 32 x 100GE ports, normal temperature, dual AC power modules)
Configured with four CE88-D10CQ-H cards:
– 315 W (100% traffic load, copper cables on 20 x 100GE ports, normal temperature, dual AC power modules)
– 338 W (100% traffic load, copper cables on 20 x 200GE ports, normal temperature, dual AC power modules)
– 345 W (100% traffic load, short-distance optical modules on 20 x 100GE ports, normal temperature, dual AC power modules)
– 420 W (100% traffic load, short-distance optical modules on 20 x 200GE ports, normal temperature, dual AC power modules)
Configured with four CE88-D8YS4DQ-H cards:
– 306 W (100% traffic load, copper cables on 8 x 400GE + 16 x 25GE ports, normal temperature, dual AC power modules)
– 406 W (100% traffic load, short-distance optical modules on 8 x 400GE + 16 x 25GE ports, normal temperature, dual AC power modules)
Configured with four CE88-D24YS2CQ-H cards:
– 305 W (100% traffic load, copper cables on 48 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules)
– 338 W (100% traffic load, short-distance optical modules on 48 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules)
Configured with four CE88-D24T2CQ-H cards:
– 381 W (100% traffic load, copper cables on 48 x 10GE electrical + 4 x 100GE ports, normal temperature, dual AC power modules)
– 388 W (100% traffic load, short-distance optical modules on 48 x 10GE electrical + 4 x 100GE ports, normal temperature, dual AC power modules)
Typical heat dissipation [BTU/hour] Configured with four CE88-D16CQ-H cards:
– 2217.8 BTU/hour (100% traffic load, copper cables on 32 x 100GE ports, normal temperature, dual AC power modules)
– 2483.9 BTU/hour (100% traffic load, short-distance optical modules on 32 x 100GE ports, normal temperature, dual AC power modules)
Configured with four CE88-D10CQ-H cards:
– 1074.8 BTU/hour (100% traffic load, copper cables on 20 x 100GE ports, normal temperature, dual AC power modules)
– 1153.3 BTU/hour (100% traffic load, copper cables on 20 x 200GE ports, normal temperature, dual AC power modules)
– 1177.1 BTU/hour (100% traffic load, short-distance optical modules on 20 x 100GE ports, normal temperature, dual AC power modules)
– 1433 BTU/hour (100% traffic load, short-distance optical modules on 20 x 200GE ports, normal temperature, dual AC power modules)
Configured with four CE88-D8YS4DQ-H cards:
– 1044.1 BTU/hour (100% traffic load, copper cables on 8 x 400GE + 16 x 25GE ports, normal temperature, dual AC power modules)
– 1385.3 BTU/hour (100% traffic load, short-distance optical modules on 8 x 400GE + 16 x 25GE ports, normal temperature, dual AC power modules)
Configured with four CE88-D24YS2CQ-H cards:
– 1040.7 BTU/hour (100% traffic load, copper cables on 48 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules)
– 1153.3 BTU/hour (100% traffic load, short-distance optical modules on 48 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules)
Configured with four CE88-D24T2CQ-H cards:
– 1300 BTU/hour (100% traffic load, copper cables on 48 x 10GE electrical + 4 x 100GE ports, normal temperature, dual AC power modules)
– 1323.9 BTU/hour (100% traffic load, short-distance optical modules on 48 x 10GE electrical + 4 x 100GE ports, normal temperature, dual AC power modules)
Static power consumption [W] Configured with four CE88-D16CQ-H cards: 569 W
Configured with four CE88-D10CQ-H cards: 297 W
Configured with four CE88-D8YS4DQ-H cards: 297 W
Configured with four CE88-D24YS2CQ-H cards: 276 W
Configured with four CE88-D24T2CQ-H cards: 330 W
Static heat dissipation [BTU/hour] Configured with four CE88-D16CQ-H cards: 1941.4 BTU/hour
Configured with four CE88-D10CQ-H cards: 1013.4 BTU/hour
Configured with four CE88-D8YS4DQ-H cards: 1013.4 BTU/hour
Configured with four CE88-D24YS2CQ-H cards: 941.7 BTU/hour
Configured with four CE88-D24T2CQ-H cards: 1126 BTU/hour
Maximum power consumption [W] Configured with four CE88-D16CQ-H cards:
– 888 W (100% traffic load, short-distance optical modules on 64 x 100GE ports, normal temperature, dual AC power modules)
– 1318 W (100% traffic load, long-distance optical modules on 64 x 100GE ports, high temperature, dual AC power modules)
– 1376 W (100% traffic load, long-distance optical modules on 48 x 100GE + 16 x 200GE ports, high temperature, dual AC power modules)
Configured with four CE88-D10CQ-H cards:
– 406 W (100% traffic load, short-distance optical modules on 40 x 100GE ports, normal temperature, dual AC power modules)
– 549 W (100% traffic load, short-distance optical modules on 40 x 200GE ports, normal temperature, dual AC power modules)
– 612 W (100% traffic load, long-distance optical modules on 40 x 100GE ports, high temperature, dual AC power modules)
– 965 W (100% traffic load, long-distance optical modules on 40 x 200GE ports, high temperature, dual AC power modules)
Configured with four CE88-D8YS4DQ-H cards:
– 531 W (100% traffic load, short-distance optical modules on 16 x 400GE + 32 x 25GE ports, normal temperature, dual AC power modules)
– 830 W (100% traffic load, long-distance optical modules on 16 x 400GE + 32 x 25GE ports, high temperature, dual AC power modules)
Configured with four CE88-D24YS2CQ-H cards:
– 410 W (100% traffic load, short-distance optical modules on 96 x 25GE + 8 x 100GE ports, normal temperature, dual AC power modules)
– 718 W (100% traffic load, long-distance optical modules on 96 x 25GE + 8 x 100GE ports, high temperature, dual AC power modules)
Configured with four CE88-D24T2CQ-H cards:
– 455 W (100% traffic load, short-distance optical modules on 96 x 10GE electrical + 8 x 100GE ports, normal temperature, dual AC power modules)
– 732 W (100% traffic load, long-distance optical modules on 96 x 10GE electrical + 8 x 100GE ports, high temperature, dual AC power modules)
Maximum heat dissipation [BTU/hour] Configured with four CE88-D16CQ-H cards:
– 3029.9 BTU/hour (100% traffic load, short-distance optical modules on 64 x 100GE ports, normal temperature, dual AC power modules)
– 4497 BTU/hour (100% traffic load, long-distance optical modules on 64 x 100GE ports, high temperature, dual AC power modules)
– 4694.9 BTU/hour (100% traffic load, long-distance optical modules on 48 x 100GE + 16 x 200GE ports, high temperature, dual AC power modules)
Configured with four CE88-D10CQ-H cards:
– 1385.3 BTU/hour (100% traffic load, short-distance optical modules on 40 x 100GE ports, normal temperature, dual AC power modules)
– 1873.2 BTU/hour (100% traffic load, short-distance optical modules on 40 x 200GE ports, normal temperature, dual AC power modules)
– 2088.1 BTU/hour (100% traffic load, long-distance optical modules on 40 x 100GE ports, high temperature, dual AC power modules)
– 3292.6 BTU/hour (100% traffic load, long-distance optical modules on 40 x 200GE ports, high temperature, dual AC power modules)
Configured with four CE88-D8YS4DQ-H cards:
– 1811.8 BTU/hour (100% traffic load, short-distance optical modules on 16 x 400GE + 32 x 25GE ports, normal temperature, dual AC power modules)
– 2832 BTU/hour (100% traffic load, long-distance optical modules on 16 x 400GE + 32 x 25GE ports, high temperature, dual AC power modules)
Configured with four CE88-D24YS2CQ-H cards:
– 1398.9 BTU/hour (100% traffic load, short-distance optical modules on 96 x 25GE + 8 x 100GE ports, normal temperature, dual AC power modules)
– 2449.8 BTU/hour (100% traffic load, long-distance optical modules on 96 x 25GE + 8 x 100GE ports, high temperature, dual AC power modules)
Configured with four CE88-D24T2CQ-H cards:
– 1552.5 BTU/hour (100% traffic load, short-distance optical modules on 96 x 10GE electrical ports + 8 x 100GE ports, normal temperature, dual AC power modules)
– 2497.6 BTU/hour (100% traffic load, long-distance optical modules on 96 x 10GE electrical ports + 8 x 100GE ports, high temperature, dual AC power modules)
Number of power modules 2
Redundant power supply 1+1 backup
Rated input voltage [V] – 2000 W AC&240 V DC power module: AC: 100 V AC to 240 V AC, 50/60 Hz; DC: 240 V DC
– 1800 W AC&240 V DC power module: AC: 100 V AC to 240 V AC, 50/60 Hz; DC: 240 V DC
– 2000 W high-voltage DC power module: 336 V DC
– 2200 W DC power module: –48 V DC to –60 V DC; +48 V DC
Input voltage range [V] – 2000 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 66 Hz; DC: 190 V DC to 290 V DC
– 1800 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 66 Hz; DC: 190 V DC to 290 V DC
– 2000 W high-voltage DC power module: 260 V DC to 400 V DC
– 2200 W DC power module: –38.4 V DC to –72 V DC; +38.4 V DC to +57 V DC
Maximum input current [A] – 2000 W AC&240 V DC power module: 10 A (100 V AC to 240 V AC); 10 A (240 V DC)
– 1800 W AC&240 V DC power module: 10 A (100 V AC to 240 V AC); 10 A (240 V DC)
– 2000 W high-voltage DC power module: 10 A (336 V DC)
– 2200 W DC power module: 63 A (–48 V DC to –60 V DC); 63 A (+48 V DC)
Rated output power [W] – 2000 W AC&240 V DC power module: 2000 W (220 V AC to 240 V AC&240 V DC), 1800 W (200 V AC to 220 V AC), 900 W (100 V AC to 130 V AC)
– 1800 W AC&240 V DC power module: 1800 W (200 V AC to 240 V AC&240 V DC), 900 W (100 V AC to 130 V AC)
– 2000 W high-voltage DC power module: 2000 W
– 2200 W DC power module: 2200 W
Certification – Compliance with safety standards
– Compliance with EMC standards
– Compliance with environment and environmental protection standards
Power supply surge protection [kV] – AC: 6 kV in common mode and 6 kV in differential mode
– HVDC: 4 kV in common mode and 2 kV in differential mode
– DC: 4 kV in common mode and 2 kV in differential mode
Types of fans Pluggable
Number of fans 3
Redundant fans The device supports 2+1 backup of fan modules that work in hot standby mode. The system can operate normally for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately.
Heat dissipation mode Air cooling
Airflow direction Port-side air intake or port-side air exhaust, depending on the fan modules and power modules that are used. The fan modules and power modules must have the same airflow direction.
Availability 0.9999964621
MTBF [year] 48.4 years
MTTR [hour] 1.86 hours
Noise at normal temperature (27°C, sound pressure) [dB(A)] Port-side air intake: < 64.3 dB(A)
Port-side air exhaust: < 65.2 dB(A)
Noise at high temperature (40°C, sound pressure) [dB(A)] Port-side air intake: < 86.1 dB(A)
Port-side air exhaust: < 87.9 dB(A)
Long-term operating altitude [m (ft.)] ≤ 5000 m (16404 ft.)
Long-term operating relative humidity [RH] 5% RH to 95% RH, non-condensing
Long-term operating temperature [°C (°F)] 0°C to 40°C (32°F to 104°F) at an altitude of 0–1800 m (0–5906 ft.)
Note: When the altitude is 1800–5000 m (5096–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
Storage altitude [m (ft.)] ≤ 5000 m (16404 ft.)
Storage relative humidity [RH] 5% to 95% RH, non-condensing
Storage temperature [°C (°F)] -40ºC to +70ºC (-40°F to +158°F)
System Management>Hardware management>Device Management>Board management>Device restart
Device restart Y

 

 

 

Отзывы

12/13/2024

Very fast delivery.

R
Ryder
Проверенный покупатель

Гарантия

Стандартная гарантийная политика

All hardware sold by ITMall includes our 3-Year Free Maintenance and 1-Year RMA Replacement Service. Please refer to our Warranty Policy for details.

  • 1-Year Advance Replacement (RMA)
  • 3-Year Free Repair Service
  • Full coverage for functionality defects
Простой процесс RMA

We streamlined the return process to minimize your network downtime. Our engineering team provides pre-return diagnostics to ensure hardware is truly defective.

  • 30-Day satisfaction guarantee return window
  • Automated RMA portal access for instant tracking
  • Restocking fee waived for functionality issues
Сертифицированная инженерная поддержка

Our products are backed by CCIE-certified engineers who provide expert guidance on compatibility, configuration, and troubleshooting at no extra cost.

  • Free pre-sales topology consultation
  • Remote troubleshooting & firmware advice
  • Simulation lab testing before dispatch
Глобальная логистика и упаковка

We ship to 85+ countries using premium anti-static packaging to ensure safety. Orders placed before 14:00 (GMT+8) are typically dispatched the same day.

  • Double-walled boxes with customer molded foam
  • Blind shipping support for channel partners
  • Real-time tracking via FedEx / DHL / UPS

Ресурсы

Для этого продукта нет доступных загрузок.

Общие вопросы

Is this product Brand New?
Yes, unless clearly marked as "Refurbished", all our products are Factory Sealed (Original New) sourced directly from authorized channels.
What is the warranty period?
We provide a comprehensive 3-Year Warranty on this item. This covers hardware defects and includes advanced replacement.
Do you offer volume discounts?
Yes! For bulk orders or project bids, please click "Quote | Help" to get a custom price proposal from our sales team.
How fast can you ship?
In-stock items ordered before 3 PM EST ship the same day. We offer overnight and 2-day shipping options via FedEx/DHL.

Остались вопросы?