ASR 9912 Fan Tray

$0.00

Condition: NOB

RMA Warranty

support team Girl Avatar

Expert Consultant Support

Solution Support ,More Discount.
Live Chat   |   Email
7*24h Online

Description

Product overview

The Cisco® ASR 9000 Series Aggregation Services Routers (ASR 9000 Series) represent an exciting new paradigm in edge and core routing, with exceptional scalability, carrier-class reliability, environmentally conscious design, incredible flexibility, and an attractive price-to-performance benchmark. The Cisco ASR 9000 Series has a wide product portfolio, ranging from the Cisco ASR 9001 (2 Rack Units [2RU]) to the Cisco ASR 9922 (44RU), with each system designed to provide true carrier-class reliability using the Cisco IOS® XR operating system, comprehensive system redundancy, and a full complement of network resiliency schemes. Finally, the Cisco ASR 9000 Series is designed to simplify and enhance the operational and deployment aspects of service-delivery networks.

Cisco ASR 9912 and ASR 9922

Specification

Model

Cisco ASR 9912

Cisco ASR 9922

Categories

Physical specifications

Height: 52.5 in. (1333.5 mm) (30 RU)

Width: 17.60 in. (447.04 mm)

Depth:

●  With door: 30.03 in. (762.76 mm)
●  Without doors: 29.25 in. (742.95mm)

Weight:

●  231.25 lb (105.11 kg) (3 PEMs and chassis)
●  389.55 lb (177.07 kg) (3 PEMs, 2 Fan Trays, 2 RP2, and 5 Fabric Card 2)

Height: 77 in. (1955.4 mm) (44 RU)

Width: 17.60 in. (447.04 mm)

Depth:

●  With doors: 30.68 in. (779.27 mm)
●  Without doors: 30.19 in. (766.82 mm)

Weight:

●  413 lb (187.73 kg) (4 PEM and chassis)
●  639.5 lb (290.7 kg) (2 RP2, 7 Fabric Cards 2, 4 Fan Trays, and 4 PEMs)

Slot orientation

Vertical

Vertical

Cisco ASR 9000 Series RSP

RSPs segregated into route processor and fabric cards

RSPs segregated into route processor and fabric cards

Route processor

Dual redundant route processors in 2 slots

Dual redundant route processors in 2 slots

Fabric cards

6 + 1 redundant fabric cards

6 + 1 redundant fabric cards

Cisco ASR 9000 Series line cards

10 line-card slots

20 line-card slots

“Commons” components

2 route processors

7 fabric cards

2 fan trays

3 PEMs (either DC or AC)

1 center fan filter, 2 side fan filters

2 route processors

7 fabric cards

4 fan trays

4 PEMs (either DC or AC)

1 center fan filter, 2 side fan filters

Reliability and availability

Fabric redundancy

Fan redundancy

Feed redundancy

Power-supply redundancy

Route-processor redundancy

Software redundancy

Fabric redundancy

Fan redundancy

Feed redundancy

Power-supply redundancy

Route-processor redundancy

Software redundancy

Rack mounting

19-in.

21- and 23-in. adapters available

19-in.

21- and 23-in. adapters available

Cabinet mounting

Yes

Note: Doors not recommended in enclosed cabinets

Yes

Note: Doors not recommended in enclosed cabinets

Wall mounting

No

No

Airflow

Front-to-back

Front-to-back

Performance

Fabric

Seven switch fabric card slots:

●  Support for 6 + 1 redundancy
●  Operate in active/active nonblocking mode
●  Built-in service-intelligence and traffic-prioritization capability

Seven switch fabric card slots:

●  Supports 6 + 1 redundancy
●  Operate in active/active nonblocking mode
●  Built-in service-intelligence and traffic-prioritization capability

Thermal

Two fan trays:

●  12 high-efficiency fans per tray
●  Variable-speed fans for optimal thermal performance
●  No single point of failure

Four fan trays:

●  12 high-efficiency fans per tray
●  Variable-speed fans for optimal thermal performance
●  No single point of failure

Power

Modularity

Pay-as-you-grow power for future scalability, available in AC and DC

Multiple power module types:

●  6 kW and 3 kW AC power modules
●  4.4 kW and 2.1 kW DC power modules

Note: Mixing of AC and DC modules is not supported

Pay-as-you-grow power for future scalability, available in AC and DC

Multiple power module types:

●  6 kW and 3 kW AC power modules
●  4.4 kW and 2.1 kW DC power modules

Note: Mixing of AC and DC modules is not supported

Redundancy

●  AC: N+N redundancy
●  DC: N+1 redundancy
●  Power module redundancy
●  A/B Feed redundancy
●  PEM redundancy
●  AC: N+N redundancy
●  DC: N+1 redundancy
●  Power module redundancy
●  A/B Feed redundancy
●  PEM redundancy

Power zones

No power zone restrictions

Fully load-sharing power infrastructure

No power zone restrictions

Fully load-sharing power infrastructure

Power input

Worldwide ranging AC (200-240V; 50-60 Hz; 16A maximum)

Worldwide ranging DC (-40 to -72V; 50A nominal, 60A maximum)

Worldwide ranging AC (200-240V; 50-60 Hz; 16A maximum)

Worldwide ranging DC (-40 to -72V; 50A nominal, 60A maximum)

Power module airflow

Front-to-back

Front-to-back

Environmental Specifications (All Entries Applicable to Cisco ASR 9912 and ASR 9922)

Operating temperature (nominal)

41 to 104°F (5 to 40°C)

Operating temperature (short-term)

23 to 131°F (-5 to 55°C)

Operating humidity (nominal) (relative humidity)

5 to 90%

Storage temperature

-40 to 158°F (-40 to 70°C)

Storage (relative humidity)

5 to 93%

Operating altitude

-60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)

Regulatory Compliance (All Entries Applicable to Cisco ASR 9912 and ASR 9922)

Network Equipment Building Standards (NEBS)

Cisco ASR 9912 and ASR 9922 Routers are designed to meet:

●  SR-3580: NEBS Criteria Levels (Level 3)
●  GR-1089-CORE: NEBS EMC and Safety
●  GR-63-CORE: NEBS Physical Protection
●  VZ.TPR.9205: Verizon TEEER

ETSI standards

Cisco ASR 9912 and ASR 9922 Routers are designed to meet:

●  EN300 386: Telecommunications Network Equipment (EMC)
●  ETSI 300 019 Storage Class 1.1
●  ETSI 300 019 Transportation Class 2.3
●  ETSI 300 019 Stationary Use Class 3.1

EMC standards emission

Cisco ASR 9912 and ASR 9922 Routers are designed to meet:

●  FCC Class 47CFR15 A
●  ICES 003 Class A
●  AS/NZS CISRP22 Class A
●  CISPR 22 (EN55022) Class A
●  VCCI Class A
●  BSMI Class A
●  IEC/EN 61000-3-12: Power Line Harmonics
●  IEC/EN 61000-3-11: Voltage Fluctuations and Flicker
●  EN55022: Information Technology Equipment (Emissions)
●  EN 50121-4: Railway EMC

EMC standards immunity

Cisco ASR 9912 and ASR 9922 Routers are designed to meet:

●  IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)
●  IEC/EN-61000-4-3: Radiated Immunity (10V/m)
●  IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)
●  IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)
●  IEC/EN-61000-4-5: Signal Surge Ports (1kV)
●  IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)
●  IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
●  IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
●  IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
●  EN55024: Information Technology Equipment (Immunity)
●  EN50082-1/EN-61000-6-1: Generic Immunity Standard
●  EN 50121-4: Railway EMC

Safety

Cisco ASR 9912 and ASR 9922 Routers are designed to meet:

●  UL/CSA/IEC/EN 60950-1
●  IEC/EN 60825 Laser Safety
●  ACA TS001
●  AS/NZS 60950
●  FDA Code of Federal Regulations Laser Safety

1 review for ASR-9912-FAN

  1. Kaden Arabic (verified owner)

    The product is firmly packed.

    1 product
Add a review

Your email address will not be published. Required fields are marked *

Good quality.The product is firmly packed.Good service.Very well worth the money.Very fast delivery.