Description
DS-C9710-V2K9 Product overview
The Cisco DS-C9710-V2K9 Multilayer Director is a high-performance and feature-rich director-class SAN switch that enables enterprise clouds and transforms large storage networks. It offers several benefits and capabilities to meet the stringent requirements of large virtualized storage environments:
1. Unified Fabric: The MDS 9710 allows you to deploy Fibre Channel, IBM Fibre Connectivity (FICON), Fibre Channel over IP (FCIP), and Fibre Channel over Ethernet (FCoE) on a single fabric. This capability provides flexibility and simplifies network architecture.
2. Operating Cost Reduction: By consolidating multiple protocols onto a single fabric, the MDS 9710 helps lower operating costs. It reduces the need for multiple switches and simplifies management, leading to cost savings in infrastructure and operational expenses.
3. Intelligent Capabilities: With its intelligent capabilities, the MDS 9710 brings advanced features and functionality to your storage network. It uses the same operating system and management interface as other Cisco data center switches, making it easier to integrate into existing environments.
4. Availability, Security, and Scalability: The MDS 9710 ensures uncompromising availability, security, and scalability. It offers features like high availability, integrated encryption, and quality of service (QoS) to protect data and meet performance requirements as your storage network grows.
5. Simplified Management: The MDS 9710 simplifies management with its unified operating system and management interface. This allows for consistent administration and reduces the learning curve for network administrators.
6. Flexibility for Future Technologies: The MDS 9710 provides the capability to flexibly integrate new technologies as they emerge. This ensures that your storage network can adapt and evolve to meet future requirements.
Product highlights
Cisco MDS DS-C9710-V2K9 offers a wide range of features and capabilities to enable enterprise clouds, transform large storage networks, and lower operating costs. Here are some of the key features:
1. Outstanding Speed: DS-C9710-V2K9supports high-speed Fibre Channel switching modules and a crossbar fabric that enables up to 3.5 Terabits per second (Tbps) of front-panel Fibre Channel throughput. This ensures line-rate, nonblocking performance for all traffic conditions with predictable performance.
2. High Availability: DS-C9710-V2K9 is designed for high availability with redundant components, including power supplies, supervisors, and fabric cards. It supports grid redundancy and N+1 fabric redundancy for increased reliability.
3. Fully Integrated SAN Analytics: The MDS 9710 incorporates state-of-the-art SAN analytics and telemetry capabilities. It uses dedicated network processors and advanced port ASICs to perform real-time analytics calculations on the line cards. The telemetry data can be streamed to any analytics-visualization platform.
4. Industry-leading Scalability: With up to 24 Tbps of Fibre Channel bandwidth, the MDS 9710 can power large storage environments. It supports a high number of Fibre Channel ports in a single chassis, making it ideal for scalability.
5. Future Readiness: The MDS 9710 is designed for future readiness. It supports in-place, online upgrades to the new fabric module, allowing for seamless migration to higher speeds such as 64-Gbps line-rate ports.
6. Intelligent Network Services: The MDS 9710 offers intelligent network services such as Virtual Storage Area Networks (VSANs), Access Control Lists (ACLs), and fabric-wide Quality of Service (QoS). It supports hardware-based VSANs, Inter-VSAN Routing (IVR), and interoperability with other Cisco MDS platforms for intelligent storage services.
7. Virtual Machine Transparency: The MDS 9710 provides deterministic hardware performance and comprehensive features for virtual machines. It supports VSANs, QoS policies, access control, performance monitoring, and data protection at the virtual machine level.
8. Comprehensive Security: The MDS 9710 supports a comprehensive security framework, including support for VSANs, zoning, ACLs, role-based access control, and Fibre Channel link encryption. It ensures data security and protection for storage environments.
9. Unified SAN Management: The MDS 9710 includes built-in storage network management through a Command-Line Interface (CLI) or Cisco Data Center Network Manager (DCNM). DCNM supports integration with third-party storage management applications for seamless management.
10. Sophisticated Diagnostics: The MDS 9710 offers intelligent diagnostics, protocol decoding, network analysis tools, and the Cisco Call Home capability for reliability, faster problem resolution, and reduced service costs.
11. Multiprotocol Architecture: The MDS 9710 supports a multilayer architecture that integrates Fibre Channel, FCoE, and FICON seamlessly. It enables connectivity for different protocols and simplifies the network architecture.
12. SAN Extension FCIP Support: The MDS 9710 supports the SAN Extension Module, which enables the deployment of large and scalable SAN extension solutions using FCIP.
Main benefits
The Cisco MDS 9710 Multilayer Director offers a range of features and benefits for SAN consolidation, enterprise-class availability, business transformation with enterprise cloud deployment, advanced traffic management, ease of management, robust security, advanced diagnostics and troubleshooting, convergence with multihop FCoE, and integrated mainframe support. Let’s explore these features in more detail:
1. SAN Consolidation: The MDS 9710 allows organizations to consolidate their storage area networks (SANs) into fewer, larger, and more manageable SANs. With industry-leading port densities and high-performance switching capabilities, organizations can scale their SANs while managing total cost of ownership (TCO). By consolidating data into larger SANs, organizations can reduce their hardware footprint and associated capital and operating expenditures.
2. Enterprise-Class Availability: The MDS 9710 is designed for high availability, with redundant components and software architecture that ensures continuous operation. The supervisor module automatically restarts failed processes, and complete synchronization between active and standby supervisor modules enables stateful failover with no disruption of traffic.
3. Business Transformation with Enterprise Cloud Deployment: The MDS 9710 supports enterprise cloud deployments with industry-leading scalability, multihop FCoE for unified fabric, robust security, predictable high performance, resilient connectivity, and advanced traffic management capabilities such as quality of service (QoS). It enables organizations to quickly scale their enterprise clouds up or down as needed while meeting stringent service level agreements (SLAs).
4. Advanced Traffic Management: The MDS 9710 offers advanced traffic management capabilities that facilitate the deployment and optimization of large-scale fabrics. Features like Virtual Output Queue (VOQ), extended buffer-to-buffer credits, port channels, Fabric Shortest Path First (FSPF)-based multipathing, and QoS help ensure optimal performance, efficient bandwidth utilization, and load balancing across multiple paths.
5. Ease of Management: The MDS 9710 provides three modes of management: Cisco MDS 9000 Family CLI, Cisco Data Center Network Manager (DCNM), and integration with third-party storage management tools. The CLI offers broad management capabilities, while DCNM simplifies day-to-day operations in virtualized data center environments. DCNM supports monitoring, provisioning, resource management, and federation of multiple DCNM servers for large-scale deployments.
6. Robust Security: The MDS 9710 offers a comprehensive security framework to protect sensitive data in enterprise networks. It includes intelligent, port-level packet inspection, ACLs for hardware enforcement of zones, Virtual Storage Area Networks (VSANs) for isolation, Inter-VSAN Routing (IVR) for controlled resource sharing, FC-SP for authentication, and Cisco TrustSec Fibre Channel link encryption for transparent data encryption.
7. Advanced Diagnostics and Troubleshooting: The MDS 9710 provides advanced diagnostics and troubleshooting tools for managing large-scale storage networks. Features like Power-On Self-Test (POST), online diagnostics, Fibre Channel traceroute, SPAN, Remote SPAN, and the embedded Fibre Channel analyzer help proactively monitor system health, verify connectivity, analyze traffic, and troubleshoot issues.
8. Convergence with Multihop FCoE: The MDS 9710 supports Fibre Channel over Ethernet (FCoE), enabling network and I/O convergence while preserving Fibre Channel constructs, latency, security, and traffic management attributes. It seamlessly coexists in a unified fabric with any-to-any connectivity for Fibre Channel and FCoE, sharing the same operating system and management plane as Cisco Nexus switches.
9. Integrated Mainframe Support: The MDS 9710 fully supports IBM System z FICON and Linux environments. It enables FICON protocol transport in cascaded and noncascaded fabrics, intermixing of FICON and open-systems FCP traffic, and in-band management of MDS 9000 Family switches from mainframe management applications. A fabric-binding feature ensures secure ISL connections.
Technical specifications
Feature
|
Description
|
Product compatibility
|
Cisco MDS 9000 Family
|
Software compatibility
|
Cisco MDS NX-OS Software Release 6.2.1 or later
Cisco MDS NX-OS Software Release 8.4.1 or later for Supervisor-4/Fabric-3 support
|
Indicators
|
Power supply LED
FAN LED
Supervisor LED
Fabric LED
Line-card module LED
|
Protocols
|
● Fibre Channel standards
● FC-PH, Revision 4.3 (ANSI INCITS 230-1994)
● FC-PH, Amendment 1 (ANSI INCITS 230-1994/AM1-1996)
● FC-PH, Amendment 2 (ANSI INCITS 230-1994/AM2-1999)
● FC-PH-2, Revision 7.4 (ANSI INCITS 297-1997)
● FC-PH-3, Revision 9.4 (ANSI INCITS 303-1998)
● FC-PI, Revision 13 (ANSI INCITS 352-2002)
● FC-PI-2, Revision 10 (ANSI INCITS 404-2006)
● FC-PI-3, Revision 4 (ANSI INCITS 460-2011)
● FC-PI-4, Revision 8 (ANSI INCITS 450-2008)
● FC-PI-5, Revision 6 (ANSI INCITS 479-2011)
● FC-FS, Revision 1.9 (ANSI INCITS 373-2003)
● FC-FS-2, Revision 1.01 (ANSI INCITS 424-2007)
● FC-FS-2, Amendment 1 (ANSI INCITS 424-2007/AM1-2007)
● FC-FS-3, Revision 1.11 (ANSI INCITS 470-2011)
● FC-LS, Revision 1.62 (ANSI INCITS 433-2007)
● FC-LS-2, Revision 2.21 (ANSI INCITS 477-2011)
● FC-SW-2, Revision 5.3 (ANSI INCITS 355-2001)
● FC-SW-3, Revision 6.6 (ANSI INCITS 384-2004)
● FC-SW-4, Revision 7.5 (ANSI INCITS 418-2006)
● FC-SW-5, Revision 8.5 (ANSI INCITS 461-2010)
● FC-GS-3, Revision 7.01 (ANSI INCITS 348-2001)
● FC-GS-4, Revision 7.91 (ANSI INCITS 387-2004)
● FCP, Revision 12 (ANSI INCITS 269-1996)
● FCP-2, Revision 8 (ANSI INCITS 350-2003)
● FCP-3, Revision 4 (ANSI INCITS 416-2006)
● FCP-4, Revision 2b (ANSI INCITS 481-2011)
● FC-SB-2, Revision 2.1 (ANSI INCITS 349-2001)
● FC-SB-3, Revision 1.6 (ANSI INCITS 374-2003)
● FC-SB-3, Amendment 1 (ANSI INCITS 374-2003/AM1-2007)
● FC-SB-4, Revision 3.0 (ANSI INCITS 466-2011)
● FC-SB-5, Revision 2.00 (ANSI INCITS 485-2014)
● FC-BB-6, Revision 2.00 (ANSI INCITS 509-2014)
● FC-BB-2, Revision 6.0 (ANSI INCITS 372-2003)
● FC-BB-3, Revision 6.8 (ANSI INCITS 414-2006)
● FC-BB-4, Revision 2.7 (ANSI INCITS 419-2008)
● FC-BB-5, Revision 2.0 (ANSI INCITS 462-2010)
● FC-VI, Revision 1.84 (ANSI INCITS 357-2002)
● FC-SP, Revision 1.8 (ANSI INCITS 426-2007)
● FC-SP-2, Revision 2.71 (ANSI INCITS 496-2012)
● FAIS, Revision 1.03 (ANSI INCITS 432-2007)
● FAIS-2, Revision 2.23 (ANSI INCITS 449-2008)
● FC-IFR, Revision 1.06 (ANSI INCITS 475-2011)
● FC-FLA, Revision 2.7 (INCITS TR-20-1998)
● FC-PLDA, Revision 2.1 (INCITS TR-19-1998)
● FC-Tape, Revision 1.17 (INCITS TR-24-1999)
● FC-MI, Revision 1.92 (INCITS TR-30-2002)
● FC-MI-2, Revision 2.6 (INCITS TR-39-2005)
● FC-MI-3, Revision 1.03 (INCITS TR-48-2012)
● FC-DA, Revision 3.1 (INCITS TR-36-2004)
● FC-DA-2, Revision 1.06 (INCITS TR-49-2012)
● FC-MSQS, Revision 3.2 (INCITS TR-46-2011)
● Fibre Channel classes of service: Class 2, Class 3, and Class F
● Fibre Channel standard port types: E, F, FL, and B
● Fibre Channel enhanced port types: SD, ST, and TE
● FCoE standard port types: VE and VF
● IEEE 802.1Qbb-2011: Priority-based Flow Control (PFC)
● IEEE 802.3db-2011: MAC address control frame for priority-based flow control
● IEEE 802.1Qaz-2011: Enhanced transmission selection for bandwidth sharing between traffic classes (ETS and DCBX)
● IP over Fibre Channel (RFC 2625)
● IPv6, IPv4, and Address Resolution Protocol (ARP) over Fibre Channel (RFC 4338)
● Extensive IETF-standards-based TCP/IP, SNMPv3, and Remote Monitoring (RMON) MIBs
● RFC 3643 and 3821 FCIP
|
Chassis slot configuration
|
● Line-card slots: 8
● Supervisor slots: 2
● Crossbar switching fabric slots: 6 * (3 fabric modules for 16-Gbps line rate and 6 fabric modules for 32-Gbps line rate)
● Fan trays: 3 fan trays at the back of the chassis
|
Switching capability per fabric
|
Number of Fabric-3 cards
|
Front-panel Fibre Channel bandwidth per slot
|
FCoE bandwidth per slot
|
1
|
512 Gbps
|
440 Gbps
|
2
|
1024 Gbps
|
880 Gbps
|
3
|
1536 Gbps
|
1320 Gbps
|
4
|
2048 Gbps
|
1760 Gbps
|
5
|
2560 Gbps
|
2200 Gbps
|
6
|
3072 Gbps
|
2640 Gbps
|
Performance and scalability
|
● Up to 24-Tbps front-panel Fibre Channel switching bandwidth and 21Tbps of FCoE bandwidth
● Supported Fibre Channel port speeds
◦ 2/4/8-Gbps autosensing; optionally configurable (2G not supported on 32-Gbps module)
◦ 4/8/16-Gbps autosensing; optionally configurable
◦ 8/16/32-Gbps autosensing; optionally configurable
◦ 10-Gbps Fibre Channel
● Buffer credits: 48-port line-rate 16-Gbps advanced Fibre Channel modules:
◦ Up to 500 per port (dedicated-mode ports) standard
◦ Up to 4095 on an individual port (dedicated-mode ports with optional Cisco MDS 9700 Enterprise Package license activated)
● Buffer credits: 48-port line-rate 32-Gbps Fibre Channel modules:
◦ Up to 500 per port (dedicated-mode ports) standard
◦ Up to 8191 on an individual port (dedicated-mode ports with optional Cisco MDS 9700 Enterprise Package license activated)
● Ports per chassis
◦ Up to 384 2/4/8-Gbps, 4/8/16-Gbps, 8/16/32-Gbps, or 10-Gbps Fibre Channel ports
● Ports per rack
◦ Up to 1152 2/4/8-Gbps, 4/8/16-Gbps, 8/16/32-Gbps, or 10-Gbps Fibre Channel ports
● Port channel: Up to 16 ports (The channel can span any speed-matched port on any module in the chassis.)
|
Features and functions
|
Fabric services
|
● Name server
● Registered State Change Notification (RSCN)
● Login services
● Fabric Configuration Server (FCS)
● Broadcast
● In-order delivery
|
Advanced functions
|
● VSAN
● IVR
● Port channel with multipath load balancing
● QoS-flow-based, zone-based
● N-port ID Virtualization (NPIV)
|
Diagnostics and troubleshooting tools
|
● POST diagnostics
● Online diagnostics
● Internal port loopbacks
● SPAN and RSPAN
● Fibre Channel traceroute
● Fibre Channel ping
● Fibre Channel debug
● Cisco Fabric Analyzer
● Syslog
● Online system health
● Port-level statistics
● Real-Time Protocol (RTP) debug
|
Network security
|
● VSANs
● ACLs
● Per-VSAN RBAC
● Fibre Channel zoning
◦ N-Port Worldwide Name (WWN)
◦ N-port FC-ID
◦ Fx-port WWN
◦ Fx-port WWN and interface index
◦ Fx-port domain ID and interface index
◦ Fx-port domain ID and port number
● FC-SP 1
◦ DH-CHAP switch-to-switch authentication
◦ DH-CHAP host-to-switch authentication
● Port security and fabric binding
● Management access
◦ SSHv2 implementing Advanced Encryption Standard (AES)
◦ SNMPv3 implementing AES
◦ SFTP
● Cisco TrustSec Fibre Channel link encryption 1
|
FICON
|
● FC-SB-6 compliant
● Cascaded FICON fabrics
● Intermix of FICON and Fibre Channel FCP traffic
● FICON CUP management interface
● Exchange-based routing ready
|
Serviceability
|
● Configuration file management
● Nondisruptive software upgrades for Fibre Channel interfaces
● Cisco Call Home feature
● Power-management LEDs
● Port beaconing
● System LEDs
● SNMP traps for alerts
● Network boot
|
Reliability and availability
|
● Online, nondisruptive software upgrades
● Stateful nondisruptive supervisor module failover
● Hot-swappable redundant supervisor modules
● Hot-swappable redundant fabric modules *
● Hot-swappable 2N redundant power
● Hot-swappable fan trays with integrated temperature and power management
● Hot-swappable Enhanced Small Form-Factor Pluggable (SFP+) optics (2/4/8/10/16/32-Gbps Fibre Channel and 10 Gigabit Ethernet). 2G speeds not supported on 32G switching module.
● Hot-swappable switching modules
● Stateful process restart
● Any module, any port configuration for port channels
● Fabric-based multipathing
● Per-VSAN fabric services
● Online diagnostics
● Port tracking
● Virtual Routing Redundancy Protocol (VRRP) for management
|
* A minimum of three fabric modules either Fabric-1 or Fabric-3 is needed to support a fully populated chassis with four Cisco MDS 9700 48-Port 16-Gbps Fibre Channel cards; four fabric modules are needed to provide N+1 redundancy. A minimum of six Fabric-1 or three Fabric-3 modules is needed to support a fully populated chassis with four Cisco MDS 9700 48-Port 32-Gbps Fibre Channel cards.
1 This feature is supported from software release NX-OS 6.2(9) onward.
|
Network management
|
● Access methods through Cisco MDS 9700 Series Supervisor-1 Module
◦ Out-of-band 10/100/1000 Ethernet port
◦ RS-232 serial console port
◦ In-band IP over Fibre Channel
● Access methods through Cisco MDS 9700 Series Fibre Channel switching module
◦ In-band FICON CUP over any IBM System z FICON Channel
● Access protocols
◦ CLI using console and Ethernet ports
◦ SNMPv3 using Ethernet port and in-band IP over Fibre Channel access
◦ FICON CUP
● Distributed Device Alias service
● Network security
◦ Per-VSAN role-based access control using RADIUS-based and TACACS+-based Authentication, Authorization, and Accounting (AAA) functions
◦ SFTP
◦ SSHv2 implementing AES
◦ SNMPv3 implementing AES
● Management applications
◦ Cisco MDS 9000 Family CLI
◦ Cisco DCNM
|
Programming interface
|
● Scriptable CLI
● Cisco Data Center Network Manager web services API
● Cisco DCNM GUI
|
Power and cooling
|
● Power supplies (3000W AC)
◦ Input: 100 to 240V AC nominal (±10% for full range); 16A nominal; 50 to 60 Hz nominal (±3 Hz for full range)
◦ Output: 1451W 50V ±4% 28A, 3.4V ±4% 15A (100 to 120V AC input), 3051W 50V ±4% 60A, and 3.4V ±-4% 15A (200 to 240V AC input)
● Air flow
◦ The Cisco MDS 9710 provides 700 Linear Feet Per Minute (LFM) average system velocity, and between 40 and 160 Cubic Feet Per Minute (CFM) total flow through each line-card slot depending on the line-card type and fan-speed setting.
◦ With the Cisco MDS 9710 using front-to-back cold-aisle and hot-aisle air flow, Cisco recommends that you maintain a minimum air space of 7 inches (17.78 cm) between walls, such as in a cabinet, and the chassis front and back air vents.
|
Power consumption (typical)
|
Cisco MDS 9710 Multilayer Director with three fabrics (Watts)
|
Ports
|
Watts
|
192
|
2695
|
288
|
3655
|
384
|
4615
|
Environmental
|
● Temperature, ambient operating: 32 to 104°F (0 to 40°C)
● Temperature, ambient nonoperating and storage: –40 to 158°F (–40 to 70°C)
● Relative humidity, ambient (noncondensing) operating: 10 to 90%
● Relative humidity, ambient (noncondensing) nonoperating and storage: 10 to 95%
● Altitude, operating: –197 to 6500 ft (–60 to 2000m)
|
Physical dimensions (H x W x D)
|
● Chassis dimensions (14 rack units [14RU]): 24.35 x 17.3 x 34.0 in. (61.9 x 43.9 x 86.4 cm)
● Cisco MDS 9700 48-Port 16-Gbps Fibre Channel line card: 1.75 x 15.9 x 21.8 in. (4.4 x 40.39 x 55.37 cm)
● Cisco MDS 9700 48-Port 32-Gbps Fibre Channel line card; 1.75 x 15.9 x 21.8 in. (4.4 x 40.39 x 55.37 cm)
● Power supply (3000W AC): 22.04 x 3.95 x 1.6 in. (55.98 x 10.03 x 4.06 cm)
● Power supply (3000W DC): 23.54 x 3.95 x 1.6 in. (59.79 x 10.03 x 4.06 cm)
● Fabric-1 module: 18.09 x 2.02 x 9.22 in. (45.95 x 5.13 x 23.42 cm)
● Fabric-3 module: 18.09 x 2.02 x 9.22 in. (45.95 x 5.13 x 23.42 cm)
● Supervisor-1 module: 2.04 x 7.5 x 21.8 in. (5.18 x 19.05 x 55.37 cm)
● Supervisor-4 module: 2.04 x 7.94 x 21.85 in. (5.18 x 20.17 x 55.5 cm)
● Fan tray: 23.54 x 5.15 x 4.09 in. (59.79 x 13.08 x 10.39 cm)
● SFP+: 0.49 x 0.54 x 2.22 in. (1.25 x 1.36 x 5.65 cm)
|
Weight
|
● Chassis (includes fans): 185.5 lb (84.2 kg)
● 48-port 16-Gbps Fibre Channel line card: 17 lb (7.71 kg)
● 48-port 32-Gbps Fibre Channel line card: 17.5 lb (7.94 kg)
● Power supply (3000W AC): 6 lb (2.7 kg)
● Fabric-1 module: 11 lb (5.0 kg)
● Fabric-3 module: 20 lb (9.07 kg)
● Supervisor-1 module: 7 lb (3.2 kg)
● Supervisor-4 module: 7.72 lb (3.5 kg)
● Fan tray: 8.5 lb (3.86 kg)
● Supervisor blank cover: 1.25 lb (0.57 kg)
● Line-card blank cover: 4.5 lb (2.04 kg)
|
Approvals and compliance
|
● Safety compliance
◦ CE Marking
◦ UL 60950
◦ CAN/CSA-C22.2 No. 60950
◦ EN 60950
◦ IEC 60950
◦ TS 001
◦ AS/NZS 3260
◦ IEC60825
◦ EN60825
◦ 21 CFR 1040
● EMC compliance
◦ FCC Part 15 (CFR 47) Class A
◦ ICES-003 Class A
◦ EN 55022 Class A
◦ CISPR 22 Class A
◦ AS/NZS 3548 Class A
◦ VCCI Class A
◦ EN 55024
◦ EN 50082-1
◦ EN 61000-6-1
◦ EN 61000-3-2
◦ EN 61000-3-3
● FIPS certified
● FIPS 140-2 Level 2
|
Ordering information
Part number
|
Product description
|
Cisco MDS 9700 Series component
|
DS-C9710
|
MDS 9710 Chassis, No Power Supplies, Fans Included
|
DS-X97-SF4-K9
|
MDS 9700 Series Supervisor-4
|
DS-X9710-FAB3
|
MDS 9710 Crossbar Switching Fabric-3 Module
|
DS-CAC97-3KW
|
MDS 9700 3000W AC power supply
|
DS-CDC97-3KW
|
MDS 9700 3000W DC power supply
|
DS-X9748-3072-TK9
|
MDS 9700 48-port 64-Gbps FC module with 48x 32Gbps SW Optics
|
DS-X9748-3072-VK9
|
MDS 9700 48-port 64-Gbps FC module with 48×64 Gbps SW Optics
|
DS-X9648-1536K9
|
MDS 9700 48-Port 32-Gbps Fibre Channel Switching Module
|
DS-X9334-K9
|
Cisco MDS 9000 Family 24/10 SAN Extension Module
|
DS-C9710-V2K9
|
MDS 9710 V2 Base Config: Chassis, 2 Sup-4, 3 Fabric-3, 4 3K AC
|
DS-C9710-V3K9
|
MDS 9710 Config: Chassis, 2 Sup-4, 6 Fabric-3, 6 3K AC
|
DS-SFP-FC32G-SW
|
32 Gbps Fibre Channel SW SFP+, LC
|
DS-SFP-FC32G-LW
|
32 Gbps Fibre Channel LW SFP+, LC
|
DS-SFP-FC16G-SW
|
16 Gbps Fibre Channel SW SFP+, LC
|
DS-SFP-FC16G-LW
|
16 Gbps Fibre Channel LW SFP+, LC
|
DS-SFP-FC16GELW
|
16 Gbps Fiber Channel ELW SFP+, LC
|
DS-SFP-FC10G-SW
|
10 Gbps Fibre Channel SW SFP+, LC
|
DS-SFP-FC10G-LW
|
10 Gbps Fibre Channel LW SFP+, LC
|
DS-SFP-FC8G-SW
|
8 Gbps Fibre Channel SW SFP+, LC
|
DS-SFP-FC8G-LW
|
8 Gbps Fibre Channel LW SFP+, LC
|
DS-SFP-FC8G-ER
|
8 Gbps Fibre Channel Extended Reach SFP+, LC
|
SFP-10G-SR
|
10GBASE-SR SFP Module
|
SFP-10G-LR
|
10GBASE-LR SFP Module
|
SFP-10G-ER
|
10GBASE-ER SFP Module
|
CAB-9K16A-AUS
|
Power cord 250VAC 16A, Australia, source plug AU20S3
|
CAB-9K16A-CH
|
Power cord 250VAC 16A, China, source plug GB16C
|
CAB-9K16A-EU
|
Power cord 250VAC 16A, Europe, source plug CEE 7/7
|
CAB-9K16A-INT
|
Power cord 250VAC 16A, international, source plug IEC 309
|
CAB-9K16A-ISR
|
Power cord 250VAC 16A, Israel, source plug SI16S3
|
CAB-9K16A-SA
|
Power cord 250VAC 16A, South Africa, source plug EL 208, SABS 164-1
|
CAB-9K16A-SW
|
Power cord 250VAC 16A, Switzerland, source plug SEV 5934-2 Type 23
|
CAB-9K16A-US1
|
Power cord 250VAC 16A, United States/Japan, source plug NEMA 6-20
|
CAB-9K16A-US2
|
Power cord 250VAC 16A, United States/Japan, source plug NEMA L6-20
|
CAB-9K20A-NA
|
Power Cord, 125VAC 20A NEMA 5-20 Plug, North America/Japan
|
CAB-9K16A-KOR
|
Power Cord 250VAC 16A, Korea, Src Plug
|
CAB-9K16A-ARG
|
Power Cord 250VAC 16A, Argentina, Src Plug IR2073-C19
|
CAB-9K16A-BRZ
|
Power Cord 250VAC 16A, Brazil, Src Plug EL224-C19
|
CAB-C19-CBN
|
Cabinet Jumper Power Cord, 250 VAC 16A, C20-C19 Connectors
|
DS-C9710-FD-MB
|
MDS 9710 – Front Door Kit
|
Licensed software
|
M97ENTK9
|
Enterprise package license for 1 MDS9700 switch
|
DCNM-SAN-M97-K9
|
DCNM for SAN License for MDS 9700
|
M97FIC1K9
|
Mainframe package license for 1 MDS9700 switch
|
L-D-M97S-AXK9
|
DCNM License for SAN Analytics on MDS9700 3 year
|
L5-D-M97S-AXK9
|
DCNM License for SAN Analytics on MDS9700 5 year
|
Spare component
|
DS-C9710=
|
MDS 9710 Chassis, Spare, No Power Supplies, Fans Included
|
DS-X97-SF4-K9=
|
MDS 9700 Series Supervisor-4
|
DS-X9710-FAB3=
|
MDS 9710 Crossbar Switching Fabric-3 Module
|
DS-CAC97-3KW=
|
MDS 9700 3000W AC power supply
|
DS-CDC97-3KW=
|
MDS 9700 3000W DC power supply
|
DS-C9710-FAN=
|
MDS 9710 FAN Tray
|
DS-X9334-K9=
|
Cisco MDS 9000 Family 24/10 SAN Extension Module, Spare
|
DS-X9748-3072-TK9=
|
MDS 9700 48-port 64-Gbps FC module with 48x 32Gbps SW Optics, Spare
|
DS-X9748-3072-VK9=
|
MDS 9700 48-port 64-Gbps FC module with 48×64 Gbps SW Optics, Spare
|
DS-X9648-1536K9=
|
MDS 9700 48-Port 32-Gbps Fibre Channel Switching Module, Spare
|
DS-SFP-FC64G-SW=
|
64 Gbps Fibre Channel SW SFP+, LC, Spare
|
DS-SFP-FC32G-SW=
|
32 Gbps Fibre Channel SW SFP+, LC, Spare
|
DS-SFP-FC32G-LW=
|
32 Gbps Fibre Channel LW SFP+, LC, Spare
|
DS-SFP-FC16G-SW=
|
16 Gbps Fibre Channel SW SFP+, LC, Spare
|
DS-SFP-FC16G-LW=
|
16 Gbps Fibre Channel LW SFP+, LC, Spare
|
DS-SFP-FC16GELW=
|
16 Gbps Fiber Channel ELW SFP+, LC, Spare
|
DS-SFP-FC10G-SW=
|
10 Gbps Fibre Channel SW SFP+, LC, Spare
|
DS-SFP-FC10G-LW=
|
10 Gbps Fibre Channel LW SFP+, LC, Spare
|
DS-SFP-FC8G-SW=
|
8 Gbps Fibre Channel SW SFP+, LC, Spare
|
DS-SFP-FC8G-LW=
|
8 Gbps Fibre Channel LW SFP+, LC, Spare
|
DS-SFP-FC8G-ER=
|
8 Gbps Fibre Channel Extended Reach SFP+, LC, Spare
|
DS-SFP-10GE-SR=SFP-10G-SR=
|
10GBASE-SR SFP Module, Spare
|
DS-SFP-10GE-LR=SFP-10G-LR=
|
10GBASE-LR SFP Module, Spare
|
SFP-10G-ER=
|
10GBASE-ER SFP Module, Spare
|
DS-CWDM8G1470=
|
1470 nm CWDM 2/4/8-Gbps Fibre Channel SFP+, Spare
|
DS-CWDM8G1490=
|
1490 nm CWDM 2/4/8-Gbps Fibre Channel SFP+, Spare
|
DS-CWDM8G1510=
|
1510 nm CWDM 2/4/8-Gbps Fibre Channel SFP+, Spare
|
DS-CWDM8G1530=
|
1530 nm CWDM 2/4/8-Gbps Fibre Channel SFP+, Spare
|
DS-CWDM8G1550=
|
1550 nm CWDM 2/4/8-Gbps Fibre Channel SFP+, Spare
|
DS-CWDM8G1570=
|
1570 nm CWDM 2/4/8-Gbps Fibre Channel SFP+, Spare
|
DS-CWDM8G1590=
|
1590 nm CWDM 2/4/8-Gbps Fibre Channel SFP+, Spare
|
DS-CWDM8G1610=
|
1610 nm CWDM 2/4/8-Gbps Fibre Channel SFP+, Spare
|
DWDM-SFP10G-xx.xx=
|
Cisco 10GBASE DWDM SFP+ Modules, Spare
|
CAB-9K16A-AUS=
|
Power cord 250VAC 16A, Australia, source plug AU20S3, Spare
|
CAB-9K16A-CH=
|
Power cord 250VAC 16A, China, source plug GB16C, Spare
|
CAB-9K16A-EU=
|
Power cord 250VAC 16A, Europe, source plug CEE 7/7, Spare
|
CAB-9K16A-INT=
|
Power cord 250VAC 16A, international, source plug IEC 309, Spare
|
CAB-9K16A-ISR=
|
Power cord 250VAC 16A, Israel, source plug SI16S3, Spare
|
CAB-9K16A-SA=
|
Power cord 250VAC 16A, South Africa, source plug EL 208, SABS 164-1, Spare
|
CAB-9K16A-SW=
|
Power cord 250VAC 16A, Switzerland, source plug SEV 5934-2 Type 23, Spare
|
CAB-9K16A-US1=
|
Power cord 250VAC 16A, United States/Japan, source plug NEMA 6-20, Spare
|
CAB-9K16A-US2=
|
Power cord 250VAC 16A, United States/Japan, source plug NEMA L6-20, Spare
|
CAB-9K20A-NA=
|
Power Cord, 125VAC 20A NEMA 5-20 Plug, North America/Japan, Spare
|
CAB-9K16A-KOR=
|
Power Cord 250VAC 16A, Korea, Src Plug, Spare
|
CAB-9K16A-ARG=
|
Power Cord 250VAC 16A, Argentina, Src Plug IR2073-C19, Spare
|
CAB-9K16A-BRZ=
|
Power Cord 250VAC 16A, Brazil, Src Plug EL224-C19, Spare
|
CAB-C19-CBN=
|
Cabinet Jumper Power Cord, 250 VAC 16A, C20-C19 Connectors, Spare
|
DS-C9710-FD-MB=
|
MDS 9710 – Front Door Kit, Spare
|
Licensed software
|
M97ENTK9=
|
Enterprise package license for 1 MDS9700 switch
|
L-M97ENTK9=
|
E-delivery Enterprise package license for 1 MDS9700 switch
|
DCNM-SAN-M97-K9=
|
DCNM for SAN License for MDS 9700
|
L-DCNM-S-M97-K9=
|
E-delivery DCNM for SAN Package Advanced Edition for MDS 9700
|
M97FIC1K9=2
|
Mainframe package license for 1 MDS9700 switch
|
L-M97FIC1K9=2
|
E-delivery Mainframe package license for 1 MDS9700 switch
|
L-D-M97S-AXK9=
|
DCNM License for SAN Analytics on MDS9700 3 year spare
|
L5-D-M97S-AXK9=
|
DCNM License for SAN Analytics on MDS9700 5 year spare
|
Anthony (verified owner) –