Description
S110-24T2S technical indicators
| Project | Describe |
|---|---|
| Dimensions (W x D x H, excluding packaging) [mm] | Basic dimensions (depth is the distance excluding the protruding structural parts of the front and rear panels): 320.0mm×210.0mm×43.6mm
Maximum size (depth is the maximum distance from the protruding port on the front panel to the protruding structure on the rear panel): 320.0mm×217.0mm×43.6mm |
| Dimensions (W x D x H, including packaging) [mm] | 460.0mm×280.0mm×90.0mm |
| Chassis height [U] | 1U |
| Chassis material | Metal |
| Weight (excluding packaging materials) [kg] | 1.90 kg |
| Weight (including packaging) [kg] | 2.50kg |
| Typical power consumption [W] | 16W |
| Typical heat dissipation value [BTU/hour] | 54.6BTU/hour |
| Maximum power consumption [W] | 17W |
| Maximum heat dissipation value [BTU/hour] | 58BTU/hour |
| Static power consumption [W] | 5W |
| MTBF [years] | 73.95years |
| MTTR [hours] | 2hours |
| Availability | > 0.99999 |
| Noise at room temperature (sound power) [dB(A)] | No fan, silent, <30 |
| Noise at normal temperature (sound pressure) [dB(A)] | No fan, silent, <20 |
| Number of card slots | 0 |
| Number of power supply slots | 0 |
| Number of fan modules | 0 |
| Switching capacity | If you need this specification, please check the product brochure or contact the product salesperson to obtain it. |
| Packet forwarding rate | If you need this specification, please check the product brochure or contact the product salesperson to obtain it. |
| Operating mode | Standard mode, port isolation, aggregation uplink, flow control off |
| Number of MAC addresses | 8K |
| Power redundancy | not support |
| Long-term working environment temperature [°C] | 0°C~+40°C (0m~1800m above sea level) |
| Operating environment temperature change limit [°C] | 1800 m to 5000 m: The maximum temperature specification decreases by 1°C every time the altitude increases by 220 m. |
| Storage temperature [°C] | -40°C~+70°C |
| Long-term working environment relative humidity [RH] | 5%RH~95%RH, non-condensing |
| Long-term working altitude [m] | 0m~5000m |
| Storage altitude [m] | 0m~5000m |
| Power supply type | Built-in AC power supply |
| Rated input voltage [V] | AC input: 100V AC ~ 240V AC; 50/60Hz |
| Input voltage range[V] | AC input: 90V AC ~ 264V AC; 45Hz ~ 65Hz |
| Maximum input current [A] | 1A |
| Memory | – |
| Flash | – |
| Console Interface Type | not support |
| Eth management network port type | not support |
| USB interface | not support |
| Real-time Clock (RTC) | not support |
| RPS Input | not support |
| Business port lightning protection [kV] | Common mode ±6kV |
| Power port lightning protection [kV] | Differential mode ±2kV, common mode ±4kV |
| Triple protection (dustproof/waterproof) | IP20 |
| Fan Type | Fanless |
| Cooling method | Natural cooling |
| Airflow direction | – |
| PoE Function | not support |
| certified product | Support EMC certification