Overview
Are you looking for really simple and affordable flash storage The HPE MSA 2062 Storage is a flash-enabled system designed to provide affordable application acceleration for small and remote office deployments. Don’t let the low cost fool you. The MSA 2062 gives you a combination of simplicity, flexibility, and advanced features you might not expect in an entry-level storage array. Starting with 3.84 TB of embedded flash capacity, you can scale your system with any combination of solid-state disks (SSDs), high-performance enterprise SAS HDDs, or low-cost midrange SAS HDDs. Capable of delivering up to 395,000 IOPS, the MSA 2062 also offers great value through the included all-inclusive software suite and 3.84 TB of flash capacity. It’s a truly simple and affordable flash storage that helps you achieve high performance while meeting challenging budgets.

HPE MSA 2062 Storage

HPE MSA 2062 Storage
| 1. | Power Switch | 5. | 12Gb SAS expansion port |
| 2. | Redundant Power and Cooling Module (AC or DC) | 6. | Controller A (Inverted) |
| 3. | Host connection ports (8/16Gb FC, 10/25GbE iSCSI, 1/10GBase-T, or 12Gb SAS depending on model) | 7. | Controller B |
| 4. | Ethernet management port |
| HPE MSA 2062 Storage | |
| Array | |
| Access Type | Block |
| Form Factor | 2U, SFF or LFF |
| Number of controllers per array | 2 |
| Number of host ports per array | 8 |
| FC host connectivity | 8/16Gb |
| iSCSI host connectivity | 10/25GbE (SFP)
1/10G Base-T (RJ-45) |
| SAS host connectivity | 12Gb |
| Cache, per array | |
| Max Read cache per array | 8TB |
| Data (read/write) cache + system memory per array | 24GB |
| Pool Capacity | Two Pools with 1 PB each |
| RAID Levels supported: | RAID 0*,1, 5, 6, 10, MSA-DP+
Notes: *Read Cache Only |
| Enclosures | |
| Expansion Drive Enclosures | 0-9 enclosures |
| LFF/SFF array/enclosure mixing | Supported |
| Maximum number of drives per array enclosure | 24 SFF or 12 LFF |
| Maximum number of drives per drive enclosure | 24 SFF or 12 LFF |
| Drive enclosure interface type | 12Gb SAS |
| Drives | |
| Maximum total HDDs per array | 240 SFF / 120 LFF |
| Maximum total SSDs per array | 240 SFF / 120 LFF |
| Max raw capacity per array enclosure | 172.8TB SFF / 203.84TB LFF |
| Max raw capacity per drive enclosure | 184.32TB SFF / 240TB LFF |
| Max raw capacity per array | 1831.68TB (All SFF) / 2363.84TB (All LFF) |
| Drive Capacities | |
| SFF SSDs | 960GB, 1.92TB, 3.84TB, 7.68TB |
| LFF SSD | 1.92TB |
| SFF HDDs | 15K: 900GB
10K: 600GB, 1.2TB, 1.8TB, 2.4TB |
| LFF HDDs | 7.2K: 6TB, 8TB, 10TB, 12TB, 14TB, 16TB, 18TB, 20TB |
| Software Features | |
| Thin Technologies | Thin Provisioning, Space Reclamation, Thin Rebuild |
| Tiering | Performance Tier, Standard Tier, Archive Tier |
| Replication | Snapshots (512), Volume Copy, Remote Snaps |
| Quality of Service | Virtual Tier Affinity |
| Bundled/Integrated Licenses | Advanced Data Services LTU standard on MSA 2062
(preinstalled on the array) |
| Maximum number of volumes per pool | 512 |
| Maximum number of volumes per array | 1024 |
| Maximum number of snapshots (included with array) | 64 |
| Maximum number of snapshots (with Advanced Data Services
License) |
512 |
| Maximum number of hosts | 512 |
| Maximum number of initiators | 1024 |
| Customer self-installable | Yes |
| Customer self-repairable | Yes |
| Customer self-upgradeable | Yes |
| Health Check analytics | Yes |
| Energy Star Certified | Yes |
| MSA 2062 | |
| Power requirements | |
| Input Power Requirements (typical-running I/O)
SFF/LFF arrays |
120VAC 3.07A, 293-361 W; 220VAC 1.58A,289-352W |
| Max Input Power | 100-240 VAC, 50/60 Hz., 4.38-2.17A; 48-60 VDC 10.4A/8.3A |
| Heat Dissipation | 1766 BTU/hr |
| Temperature and Humidity Ranges | |
| Operating Temperature | ASHRAE A3 5°C to 40°C, -12°C DP & 8 to 24°C DP
(Derate maximum allowable dry-bulb temperature 1°C/175m above 900m) |
| Shipping Temperature | -40°F to 158°F (-40°C to 70°C) |
| Operating Humidity | Up to 85% RH |
| Non-Operating Humidity | Up to 90% RH @ 30°C |
| Physical | |
| Height | 3.5 in (8.9 cm) |
| Depth (Back of chassis ear to controller latch) | 20.0 in (50.8 cm) |
| Depth (Front of chassis ear to back of cable bend) | 26.4 in (66.9 cm) |
| Width (Chassis only) | 17.5 in (44.5 cm) |
| Width (Chassis with bezel ear caps) | 19.0 in (48.3 cm) |
| Weight LFF Enclosure | |
| Chassis empty | 11 lb (5 kg) |
| Controller enclosure (fully populated with FRUs and disks) | 71 lb (32 kg) |
| Expansion enclosure (fully populated with FRUs and disks) | 62 lb (28 kg) |
| Weight SFF Enclosure | |
| Chassis empty | 11 lb (5 kg) |
| Controller enclosure (fully populated with FRUs and disks) | 66 lb (30 kg) |
| Expansion enclosure (fully populated with FRUs and disks) | 55 lb (25 kg) |
| Acoustic Ratings | |
| Sound Power | A weighted sound power LWAd – 8.3 B |
| Sound Pressure | A weighted sound pressure LpAm – 74dBA |
| Shock and Vibration | |
| Shock, Operational | 5G, 11 ms |
| Shock, Non-Operational | 15G, 10ms |
| Vibration, Operational | 5-500Hz, 0.18 Grms |
| Vibration, Non-Operational | x-axis (5-300Hz) 0.8 Grms
z-axis (5-300Hz) 1.2 Grms |
| Altitude | |
| Altitude, operating | 3000m (10,000 feet) |
| Altitude, non-operating | 12,192m (40,000 feet) |
Configuration Information
| MSA 2062 Storage Systems | ||
| Description | SKU | |
| HPE MSA 2062 16Gb Fibre Channel SFF Storage | R0Q80B | |
| HPE MSA 2062 10GbE iSCSI SFF Storage | R0Q82B | |
| HPE MSA 2062 12Gb SAS SFF Storage | R0Q84B | |
| HPE MSA 2062 10GBASE-T iSCSI SFF Storage | R7J71B | |